期刊文献+

新型辐射剂量测量计:聚合体凝胶剂量计 被引量:1

New Radiation Dosimetry: Polymer Gels
下载PDF
导出
摘要 新的更为复杂的放射治疗技术要求辐射剂量计能够准确的测量三维剂量分布,提供高的空间分辨率。聚合体凝胶剂量计是最近才发展的新型剂量计,能够很好的解决三维剂量分布测量的问题。现综述聚合体凝胶剂量计的原理、制备、特性、成像、刻度方法和医学应用。 New, complex radiotherapy delivery system techniques require dosimeters that are able to measure three-dimensional dose distributions accurately and with good spatial resolution. Polymer gel is an emerging new dosimeter being applied to thesechallenges. The review gives the concepts of polymer gel dosimetry used for medicine, including principles, manufacture, characteristics, imaging, calibration method, and medical application.
出处 《中国医学物理学杂志》 CSCD 2004年第1期1-3,18,共4页 Chinese Journal of Medical Physics
基金 国家自然科学基金资助项目(30170233)
关键词 聚合体凝胶剂量计 核磁共振 放射治疗 polymer gel dosimetry nuclear magnetic resonance radiotherapy
  • 相关文献

参考文献19

  • 1[1]Charlesby A. Radiation chemistry of polymers[M]. In:Farhataziz,Rodgers MA J, editors. Radiation chemistry. Weinheim, Germany:Wiley-VCH, 1987.
  • 2[2]Maryanski MJ, Gore JC, Kennan RP, et al. NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: a new approach to 3D dosimeters by MRI [J]. Magn Reson Imaging, 1993,11:253~258.
  • 3[3]Maryanski MJ, Schulz RJ, Ibbott GS, et al. Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeter[J]. Phys Med Biol., 1994,39:1437~1455.
  • 4[4]Baldock C, Burford RP, Billingham NC, et al. Experimental procedure for the manufacture and calibration of polyacrylamide gel (PAG) for magnetic resonance imaging (MRI) radiation dosimetry[J]. Phys Med Biol., 1998.43:695-702.
  • 5[5]Fong PM, Keil DC, Does MD, et al. Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere[J]. Phys Med Biol., 2001,46(12): 3105~3113.
  • 6[6]Spevacek V, Novotny JJ, Dvorak P, et al. Temperature dependence of polymer-gel dosimeter nuclear magnetic resonance response [J].Med Phys., 2001,28(11):2370~2378.
  • 7[7]Maryanski MJ,Audet C, Gore JC.Fffects of crosalinking and temperature on the dose response of a BANG polymer gel dosimeter[J]. Phys Med Biol., 1997,42:303~311.
  • 8[8]Jirasek AI, Duzenli C.Effects of erosslinker fraction in polymer gel dosimeters using FT Raman speetroeeopy[J]. Phys Med Biol., 2001,46(7):1949~1961.
  • 9[9]Novotny JJ, Spevacek V, Dvorak P, et al. T. Energy and dose rate dependence of BANG-2 polymer-gel dosimeter [J]. Med Phys.,2001,28(1 1):2379~2386.
  • 10[10]Lepage M, Whittaker AK, Rintoul L, Back S et al. Modelling of post-irradiation events in polymer gel dosimeters [J]. Phys Med Biol., 2001,46(11):2827-39.

同被引文献25

  • 1戴建荣,胡逸民,张红志,关莹,张可,王闯.针对患者调强放射治疗计划的剂量学验证[J].中华放射肿瘤学杂志,2004,13(3):229-233. 被引量:65
  • 2MundtAJ,RoeskeJC.临床调强放射治疗学.姜炜,崔世民,译.北京:人民卫生出版社,2011:175-191.
  • 3Baldock C, De Deene Y, Doran S, et al. Polymer gel dosimetry. Phys Med Bio1,2010 ,55 : 1-63.
  • 4Kairn T,Taylor ML,Crowe SB,et al. Monte Carlo veil? cation of gel dosimetry ts for stereotactic radiotherapy. Phys Med Bio1,2012,57:3359-3369.
  • 5MacDougall ND,Pitchford WG,Smith MA. A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry. Phys Med Bio1,2002,47 : 107-121.
  • 6Day M J, Stein G. Chemical effects of Iionizing radiation in some Gels. Nature, 1950,166 : 146-147.
  • 7Andrews HL, Murphy RE, LeBrun EJ. Gel dosimeter for depth- dose measurements. Rev Sci Instrum, 1957,28:329-332.
  • 8Gore JC, Kang YS, Schulz RJ. Measurement of radiation dose distributions by nuclear magnetic resonance(NMR) imaging. Phys Med Biol, 1984,29 : 1189-1197.
  • 9Taylor ML, Franich RD, Trapp JV, eta|. A comparative study of the effect of calibration conditions on the water equivalence of a range of gel dosimeters. IEEE Trans Nucl Sci,2009,56:429-436.
  • 10Schreiner LJ. Review of Filcke gel dosimeters. J Phys,2004,3:9- 21.

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部