摘要
目的 探讨内镜直视下水囊扩张治疗食道狭窄的疗效。方法 应用电子胃镜及水囊导管扩张器在直视下治疗食道狭窄 86例。结果 该组扩张前口径 0 .6~ 1.0cm者 2 4例 ,0 .3~ 0 .5cm者 5 5例 ,<0 .3cm者 7例 ,扩张后症状改善 ,口径 >1.2cm显效者 4 9例 ,口径 0 .6~ 1.1cm有效者 34例 ,有效率 96 .4 % ,无效 3例。结论 该方法操作简单 ,安全性好 ,病人痛苦小 ,疗效迅速。
Objective:The efficacy of using water balloon dilator to treat esophageal stenosis was evaluated.Methods:The electronic gastroscopy and MAXFORCE TTS water balloon catheter dilator were adopted to dilate esophageal stenosis in 86 patients.Results:The calibres of the stenotic orifice is 0.6~1.0 cm in 24 cases,0.3~0.5 cm in 55 cases and less than 0.3 cm in 7 cases.After endoscopy therapy the calibres was dilated to 0.6~1.1 cm in 34 cases and more than 1.2 cm in 49 cases with significant effects. The rate of effect is 96.4%. Conclusion:The endoscopic water balloon dilation is easy to master with high efficiency and safety.
出处
《中国内镜杂志》
CSCD
2004年第1期16-17,共2页
China Journal of Endoscopy
关键词
内镜
食道狭窄
水囊扩张
endoscopy
esophageal stenosis
water balloon dilator