摘要
根据CT灌注的原理,提出通过计算MTT,rCBV,rCBF等特征参数方法来描述血流的变化,并应用在自己开发的CT血流灌注软件中。实验表明,该系统能准确的检测出血流变化情况。
According to the principle of CT perfusion, we present a set of methods to calculate the corresponding parameters,in order to indicate the change of blood flow by computing the characteristic parameters such as MTT, rCBV and rCBF, and intergrate them in the CT blood perfusion software. Experimental results show that this system can accurately detect the variety of blood flow.
出处
《中国医疗器械杂志》
CAS
2004年第1期4-6,15,共4页
Chinese Journal of Medical Instrumentation
关键词
CT灌注成像系统
血流
计算MTT.rCBV.rCBF
急性脑缺血
CT blood perfusion, mean transfer time(MTT), regional cerebral blood volume(rCBV) regional cerebral blood flow(rCBF)