摘要 随着中国水电事业的发展和计算机监控系统在水电站中应用的日益广泛,计算机监控系统与外围设备的接口设计规范化已刻不容缓。计算机监控系统与外围设备接口设计规范化能够达到理顺和规范接口设计、提高水电站自动化水平、方便运行维护的目的。接口设计规范化需要根据工程规模、水电站所采用的控制方式和外围设备重要程度等多种因素,综合确定计算机监控系统与外围设备的接口。 The standardization of the interface design between computer monitoring and control system (CMCS) and its peripheral equipment is a task which brooks no delay along with the development of the hydropower cause of our country as well as the wide application of the CMCS to hydroelectric stations. The standardization of the interface design can raise the automation level of the hydropower station and make the operation and maintenance convenient. The interface between the CMCS and its peripheral equipment is determined according to many factors such as the scale of the project, the control mode to be adopted and the importance of the peripheral equipment.
出处 《水电自动化与大坝监测》 2004年第1期9-11,共3页 HYDROPOWER AUTOMATION AND DAM MONITORING
关键词 水电站 计算机监控系统 外围设备 接口设计 hydropower station computer monitoring and control system peripheral equipment interface design