期刊文献+

Monte-Carlo统计迭代图像重建算法 被引量:5

Monte-Carlo Statistical Iteration Image Reconstruction Algorithm
下载PDF
导出
摘要 线性衰减系数图像重建是层析γ扫描(TGS)的一个核心问题。本文从粒子输运方程出发,应用Monte Carlo方法,提出了一种基于Monte Carlo方法的统计迭代图像重建算法。模拟结果表明,与一般TGS图像重建算法相比,该重建算法的重建图像误差大为减小,能够满足TGS装置的要求。 Linear attenuation coefficient image reconstruction is an important problem in tomographic gamma scanning(TGS). The MonteCarlo statistical iteration image reconstruction algorithm according to particle transport theory and MonteCarlo method is presented. Simulating results indicate that the image reconstruction errors are reduced greatly by the new reconstruction algorithm comparing with general TGS algorithm. It can meet the requirements of TGS device.
出处 《原子能科学技术》 EI CAS CSCD 2003年第6期555-557,共3页 Atomic Energy Science and Technology
关键词 MONTE-CARLO法 图像重建 层析γ扫描 TGS 线性衰减系数图像 探测器 tomographic gamma scanning linear attenuation coefficient Monte-Carlo method image reconstruction iteration algorithm
  • 相关文献

参考文献1

  • 1张全虎.[D].北京:中国原子能科学研究院放射化学研究所,2001.

同被引文献21

  • 1朱文凯,陈军,熊建平,陈坤,陈益军.ISOCS系统无源效率刻度测量方法的准确性检验[J].核电子学与探测技术,2005,25(3):287-290. 被引量:33
  • 2肖雪夫.[D].北京:中国原子能科学研究院保健物理部,2001.
  • 3ROBERT J, ESTEP T H, PRETTYMAN S G. Tomographic gamma scanning to assay heterogeneous radioactive waste[J]. Nuclear Science and Engineering, 1994, 118: 145-152.
  • 4Prettyman T H, Betts S E, Taggart D P, et al. Field Experience with a Mobile Tomographic Nondestructive Assay System. Los Alamos National Laboratory, 1995. LA-UR-95-3501.
  • 5Wang T F, Martz H E, Roberson G P, et al. Three dimensional imaging of a molten-salt-extracted plutonium button using both active and passive gamma-ray computed tomography. Nucl Instrum Methods Phys Res A, 1994, 353:672-677.
  • 6Goodman D, Jackson J A, Martz H E, et al. An Active And Passive Computed Tomography Algorithm With A Constrained Conjugate Gradient Solution. Lawrence Livermore National Laboratory, 1998. UCRL-JC-130818.
  • 7Robert J E, Thomas H P, Sheppard G A. Tomographic gamma scanning to assay heterogeneous radioactive waste. Nucl Sci Eng, 1994, 118: 145-152.
  • 8Venkataraman R, Croft S, Villani M, et al. Performance study of the tomographic gamma scanner for the radioassay of drums. In: Proceedings of 45th Annual INMM Meeting. Orlando: FL, 2004. 18-22.
  • 9Croft S, Venkataraman R, Villani M. Characterizing a tomographic gamma scanner. In: Proceedings of 45th Annual INMM Meeting. Orlando: FL, 2004.18-22.
  • 10Bronson F L, Wang L. Validation of the MCNP Monte Carlo code for germanium detector gamma effieiency calibrations. In: Proceedings of Waste Management'96. Tucson: AZ, 1996.

引证文献5