摘要 利用试验资料,对蒸散面积2m^2和4m^2两种尺寸蒸渗计测量蒸散量的差异及原因进行了研究。结果表明:2m^2蒸渗计与4m^2蒸渗计所测蒸散量具有很好的一致性,但2m^2蒸渗计所测蒸散量总体要略偏大,日蒸散量平均偏大4%,月蒸散量平均偏大10%,年蒸散量相对偏大5%;典型天气条件下,2m^2蒸渗计和4m^2蒸渗计所测蒸散量的日变化过程基本相同,小时蒸散量的差异表现为晴天时白天显著偏大、夜晚略有偏小,阴天时白天略偏大、夜晚较接近,雨天时白天、夜晚均非常接近的特征。晴天和阴天时,2m^2蒸渗计比4m^2蒸渗计测量日蒸散量分别偏大1.78mm和0.12mm,雨天时偏小0.11mm;2m^2蒸渗计比4m^2蒸渗计测量蒸散量总体偏大的原因,主要是2m^2蒸渗计土壤温度显著高于4m^2蒸渗计和建造时间不同导致土体内部土壤湿度产生差异。 Based on observed data,the difference of actual evapotranspiration and its causes are analyzed by comparing the lysimeter with evaporation area of 2 square meters(referred to as 2 m^2 lysimeter)and the lysimeter with evaporation area of 4 square meters(referred to as 4 m^2 lysimeter).The results showed that measured evapotranspiration by two lysimeters was in good consistency,but the 2 m^2 lysimeter' sevapotranspiration was generally slightly larger than the 4 m^2 lysimeter with 4% more for daily evapotranspiration,10% more for monthly evapotranspiration,and 5% more for annual evapotranspiration;Under different types of synoptic conditions,the two lysimeter's evapotranspiration had a same diurnal variation.In sunny days and cloudy days,hourly evapotranspiration measured by the 2 m^2 lysimeter was larger than4 m^2 lysimeter during the day,but slightly smaller or very close during the night.The hourly evapotranspiration measured by the two lysimeters was very close in the rainy days.The daily evapotranspiration measured by the 2m^2 lysimeter is 1.78 mm more than the 4 m^2 lysimeter in the sunny days and 0.12 mm more in the cloudy days,respectively,and 0.11 mm less in the rainy days;Analysis the reasons for the 2 m^2 lysimeter measured evapotranspiration is generally slightly larger than4 m^2 lysimeter,on the one hand,the soil temperature of 2m^2 lysimeter is significantly higher than that of 4 m^2 lysimeter.On the other hand,it can be the different construction time of two sizes of lysimeters caused the soil moisture to produce difference,resulted in the difference of evapotranspiration.
出处 《中国沙漠》 CSCD 北大核心 2017年第1期167-174,共8页 Journal of Desert Research
基金 国家公益性行业科研专项(GYHY201106043) 国家自然科学基金项目(41175011)
关键词 蒸渗计 蒸散量 土壤温度 土壤湿度 差异 lysimeter evapotranspiration soil temperature soil moisture difference
  • 相关文献

参考文献19

二级参考文献361

共引文献345

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部