期刊文献+

Novel infrared differential optical absorption spectroscopy remote sensing system to measure carbon dioxide emission 被引量:1

Novel infrared differential optical absorption spectroscopy remote sensing system to measure carbon dioxide emission
下载PDF
导出
摘要 A CO_2 infrared remote sensing system based on the algorithm of weighting function modified differential optical absorption spectroscopy(WFM-DOAS) is developed for measuring CO_2 emissions from pollution sources. The system is composed of a spectrometer with band from 900 nm to 1700 nm, a telescope with a field of view of 1.12?, a silica optical fiber, an automatic position adjuster, and the data acquisition and processing module. The performance is discussed,including the electronic noise of the charge-coupled device(CCD), the spectral shift, and detection limits. The resolution of the spectrometer is 0.4 nm, the detection limit is 8.5 × 10^(20)molecules·cm^(-2), and the relative retrieval error is < 1.5%.On May 26, 2018, a field experiment was performed to measure CO_2 emissions from the Feng-tai power plant, and a twodimensional distribution of CO_2 from the plume was obtained. The retrieved differential slant column densities(dSCDs)of CO_2 are around 2 × 10^(21) molecules·cm^(-2) in the unpolluted areas, 5.5 × 10^(21)molecules·cm^(-2) in the plume locations most strongly affected by local CO_2 emissions, and the fitting error is less than 2 × 10^(20)molecules·cm^(-2), which proves that the infrared remote sensing system has the characteristics of fast response and high precision, suitable for measuring CO_2 emission from the sources. A CO_2 infrared remote sensing system based on the algorithm of weighting function modified differential optical absorption spectroscopy(WFM-DOAS) is developed for measuring CO_2 emissions from pollution sources. The system is composed of a spectrometer with band from 900 nm to 1700 nm, a telescope with a field of view of 1.12?, a silica optical fiber, an automatic position adjuster, and the data acquisition and processing module. The performance is discussed,including the electronic noise of the charge-coupled device(CCD), the spectral shift, and detection limits. The resolution of the spectrometer is 0.4 nm, the detection limit is 8.5 × 10^(20)molecules·cm^(-2), and the relative retrieval error is < 1.5%.On May 26, 2018, a field experiment was performed to measure CO_2 emissions from the Feng-tai power plant, and a twodimensional distribution of CO_2 from the plume was obtained. The retrieved differential slant column densities(dSCDs)of CO_2 are around 2 × 10^(21) molecules·cm^(-2) in the unpolluted areas, 5.5 × 10^(21)molecules·cm^(-2) in the plume locations most strongly affected by local CO_2 emissions, and the fitting error is less than 2 × 10^(20)molecules·cm^(-2), which proves that the infrared remote sensing system has the characteristics of fast response and high precision, suitable for measuring CO_2 emission from the sources.
作者 Ru-Wen Wang Pin-Hua Xie Jin Xu Ang Li 王汝雯;谢品华;徐晋;李昂(Key Laboratory of Environmental Optics and Technology Anhui Institute of Optics and Fine MechanicsChinese Academy of Sciences;University of Science and Technology of China;CAS Center for Excellence in Urban Atmospheric Environment Institute of Urban Environment Chinese Academy of Sciences)
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第1期353-359,共7页 中国物理B(英文版)
基金 Project supported by the Key Program of the National Natural Science Foundation of China(Grant No.41530644)
关键词 weighting function modified DIFFERENTIAL optical ABSORPTION spectroscopy(WFM-DOAS) INFRARED instrument CO2 emission SOURCES weighting function modified differential optical absorption spectroscopy(WFM-DOAS) infrared instrument CO_2 emission sources
  • 相关文献

同被引文献16

引证文献1

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部