摘要
灯具CCC强制认证采用的国标GB 7000.1-2015《灯具第1部分:一般要求与试验》要求使用了安全标准中不免除视网膜蓝光危害评估的光源的灯具,应根据IEC/TR 62778《应用IEC 62471评价光源和灯具的蓝光危害》进行评估。本文对IEC TR 62778关于蓝光危害信息传递方面进行了详细研究和大量试验后发现:简单地依据'亮度守恒定律'作为传递初级光源蓝光危害值至下一级包含有这些初级光源的照明产品的蓝光危害上限值的结论是不成立的。
IEC/TR 62778'Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires'is used to evaluate lamps that do not be exempted from retinal blue light hazard assessment in the National Standard GB 7000.1-2015'Luminaires-Part:1:General requirements and tests'adopted by China Compulsory Certification of luminaires.In this paper,through the research and experiments on the transmission of blue light hazard in IEC TR 62778,it is found that:the conclusion enabling the flow of information from the blue light hazard value of the primary source to the blue light hazard of the lighting products containing these primary sources based on the'law of conservation of luminance'is not true.
作者
邵广嘉
SHAO Guangjia(Guangdong Testing Institute of Product Quality Supervision,Guangzhou 510670,China)
出处
《中国照明电器》
2019年第7期1-4,共4页
China Light & Lighting
基金
广东省省级科技计划项目“广东省NQI-质量安全科技协同创新中心”(2018B020207007)
广东省省级科技计划项目“面向LED光组件大规模制造的光色品质精确控制全自动装备研制”(2015B010133004)
2015年省级财政技术研究与开发补助费用项目“LED照明产品光色品质控制研究及装备产业化应用”(粤财工[2015]639号)