期刊文献+

Estimating mean trabecular bone spacing based on the combination of Hilbert transform and fundamental frequency estimation

Estimating mean trabecular bone spacing based on the combination of Hilbert transform and fundamental frequency estimation
原文传递
导出
摘要 Ultrasonic backscatter signals from cancellous bone are sensitive to the microstructure of trabecular bone,and thus enable the feasibility to extract microstructural information of trabecular bone.The mean trabecular bone spacing(MTBS)is an important parameter for characterizing bone microstructure.This paper proposes an MTBS estimation method based on the combination of Hilbert transform and fundamental frequency estimation(CHF). The CHF was verified with ultrasonic backscatter signals from simulations and in vitro measurements at a central frequency of 5MHz.The CHF method was compared with the simplified inverse filter tracking(SIFT)method,Simons' Quadratic Transformation(QT)method,Singular Spectrum Analysis(SSA)method,and Spectral Autocorrelation(SAC)method.Monte-Carlo simulations were performed by varying the MTBS,signal-to-noise ratio(SNR),standard deviation of regular spacing(SDRS),amplitude ratio of diffuse scattering to regular scattering(Ad)and frequency dependent attenuation(nBUA).The simulation results showed that the CHF method had a better performance in MTBS estimation under almost all the examination conditions except for SNR.The estimation percentage correct(EPC)was greater than 90% when the MTBS was in the range of 0.4to 1.4mm.In the in vitro measurements,the estimated EPC by the CHF method was91.25±7.81%(mean±standard deviation).A significant correlation was observed for the CHF-estimated MTBS and micro-computed tomography(μ-CT)-measured values(R^2=0.75,p<0.01).These results demonstrate that the CHF method is anti-interference for MTBS estimation and can be used to estimate trabecular bone spacing. Ultrasonic backscatter signals from cancellous bone are sensitive to the microstructure of trabecular bone,and thus enable the feasibility to extract microstructural information of trabecular bone.The mean trabecular bone spacing(MTBS)is an important parameter for characterizing bone microstructure.This paper proposes an MTBS estimation method based on the combination of Hilbert transform and fundamental frequency estimation(CHF). The CHF was verified with ultrasonic backscatter signals from simulations and in vitro measurements at a central frequency of 5MHz.The CHF method was compared with the simplified inverse filter tracking(SIFT)method,Simons' Quadratic Transformation(QT)method,Singular Spectrum Analysis(SSA)method,and Spectral Autocorrelation(SAC)method.Monte-Carlo simulations were performed by varying the MTBS,signal-to-noise ratio(SNR),standard deviation of regular spacing(SDRS),amplitude ratio of diffuse scattering to regular scattering(Ad)and frequency dependent attenuation(nBUA).The simulation results showed that the CHF method had a better performance in MTBS estimation under almost all the examination conditions except for SNR.The estimation percentage correct(EPC)was greater than 90% when the MTBS was in the range of 0.4to 1.4mm.In the in vitro measurements,the estimated EPC by the CHF method was91.25±7.81%(mean±standard deviation).A significant correlation was observed for the CHF-estimated MTBS and micro-computed tomography(μ-CT)-measured values(R^2=0.75,p<0.01).These results demonstrate that the CHF method is anti-interference for MTBS estimation and can be used to estimate trabecular bone spacing.
出处 《Science Foundation in China》 CAS 2017年第3期57-71,共15页 中国科学基金(英文版)
基金 supported by the NSFC(11327405,11504057&11525416)
关键词 超声的反散射 意味着 trabecular 骨头间距评价 Hilbert 变换和基本频率评价 Cancellous 骨头微观结构 Ultrasonic backscatter Mean trabecular bone spacing estimation Hilbert transform and fundamental frequency estimation Cancellous bone microstructure
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部