期刊文献+

日立扫描电镜真空系统的维护

Maintenance and Troubleshooting of Vacuum System of Hitachi Scanning Electron Microscope
下载PDF
导出
摘要 电镜真空体系对确保仪器正常运行和图片质量十分重要。本文介绍了日立扫描电镜的真空系统的组成及在运行中出现的故障和故障消除的方法,为实现扫描电镜的正常工作提供了有利保障。 The maintenance,operation and trouble-shooting of the vacuum system,installed in HITACHI scanning electron microscope,were addressed briefly in a thought provoking way.To begin with,the negative influence of the unstable vacuum on the image quality,service life of filament,cleanliness of electron optics and normal operation of SEM was discussed with specific examples.Second,the possible solutions to the common technical problems,including,but not limited to the no response of pneumatic valve,diffusion pump breakdown,abnormal oil temperature,starting failure of mechanical pump,and deterioration or contamination of cooling water,were suggested.And finally,when it comes to safe operation and regular maintenance of the vacuum system,some musts and must-nots were recommended.
作者 潘桂玲 Pan Guiling(Key Laboratory of Functional Polymer Materials of the Ministry of Education,College of Chemistry,Nankai University,Tianjin 300071,China)
出处 《真空科学与技术学报》 EI CAS CSCD 北大核心 2019年第9期811-814,共4页 Chinese Journal of Vacuum Science and Technology
基金 国家973计划资助项目(No.2015CB251100)
关键词 扫描电镜 真空系统 油扩散泵 机械泵 真空油 维护 SEM Vacuum system Mechanical pump Oil diffusion pump Maintaining