期刊文献+

核电厂高压加热器检漏技术研究 被引量:4

Research of leak detection technology for high-pressure heater used in nuclear power plant
下载PDF
导出
摘要 泄漏是核电厂高压加热器常出现的故障之一,作为核电厂常规岛的重要组成部分,一旦高压加热器出现故障,将极大影响机组安全稳定的运行。本文主要介绍了氦检漏和真空压差检漏技术在高压加热器传热管及密封焊泄漏检测中的应用,实践证明,此方法可大大提高检测检修效率。 Leakage is one of the most frequent failures of high-pressure heater in nuclear power plants. As an important part of CI, high-pressure heater plays a key role in determining the smooth and stable operation of the equipment. This paper mainly introduces the application of helium leak detection and vacuum differential pressure leak detection in heat transfer pipe and seal welding of high-pressure heater, which can largely improve the efficiency of testing and repairing.
作者 姜伟 苗振宇 JIANG Wei;MIAO Zhen-yu(State Nuclear Power Plant Service Company,Shanghai 200233,China)
出处 《真空》 CAS 2019年第1期49-51,共3页 Vacuum
关键词 高压加热器 氦检漏 真空压差法检漏 high-pressure heater helium leak detection vacuum differential leak detector
  • 相关文献

同被引文献33

引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部