摘要
2014年修订完成Q/GDW 1389—2014《扩径导线架线施工工艺导则》。以贯彻安全可靠、经济合理、技术先进、环境友好为技术原则,结合扩径导线相应研究成果,从相应条款的技术思路、基本原理、操作方法及注意事项等方面解读Q/GDW 1389—2014的技术要求,为指导架空送电线路扩径导线架线施工提供重要依据。
Q/GDW 1389-2014《Construction Technology Guide for the Tension Stringing of Expanded Diameter Conductors for Overhead Transmission Line》has been revised in 2014. To implement the technological principles of security, reliability, reasonable economy, advanced technology and environment-friendliness, combining corresponding research results concerning expanded diameter conductors, a detailed reading about the technical requirement of the construction technology guide for the tension stringing of expanded diameter conductors for overhead transmission line is made. It is interpreted from aspects of technical ideas, basic principle, operational approach and announcements of relative provisions. The technology guide provides important basis for the construction of the tension stringing of expanded diameter conductors for overhead transmission line.
出处
《智能电网》
2014年第11期52-55,共4页
Smart Grid
关键词
扩径导线
施工工艺
张力放线
顺压
倒压
expanded diameter conductors
construction technology
tension stringing
crimping from one side of splice to another