期刊文献+

Systematic design method for PI controller with Virtual Resistor-based Active Damping of LCL filter 被引量:4

下载PDF
导出
摘要 The Virtual Resistor based Active Damping(VR-AD) is widely employed in converters connected to the grid via LCL filters in order to mitigate the inherent resonance of the filters. Nevertheless, in digitally controlled systems, the PWM and the calculating delays modify the system characteristics in terms of frequency and phase, thus destabilizing the system and degrading the VR-AD performances, mainly in low switching frequencies. Moreover, the stability of the system is greatly affected under weak grid operation characterized by large grid impedance variation. This paper solves these problems by proposing a systematic, robust and optimized design procedure of voltage oriented PI control(VOC) with VRAD. The considered design procedure ensures robust control(sufficient stability margins) and high quality of grid current(reduced steady-state error and minimized THD value) despite the negative impact of digital time delay, grid impedance variation and filter parameters change. Simulation and experimental results are presented to show robustness and efficiency of the suggested design procedure. The Virtual Resistor based Active Damping(VR-AD) is widely employed in converters connected to the grid via LCL filters in order to mitigate the inherent resonance of the filters. Nevertheless, in digitally controlled systems, the PWM and the calculating delays modify the system characteristics in terms of frequency and phase, thus destabilizing the system and degrading the VR-AD performances, mainly in low switching frequencies. Moreover, the stability of the system is greatly affected under weak grid operation characterized by large grid impedance variation. This paper solves these problems by proposing a systematic, robust and optimized design procedure of voltage oriented PI control(VOC) with VRAD. The considered design procedure ensures robust control(sufficient stability margins) and high quality of grid current(reduced steady-state error and minimized THD value) despite the negative impact of digital time delay, grid impedance variation and filter parameters change. Simulation and experimental results are presented to show robustness and efficiency of the suggested design procedure.
出处 《Global Energy Interconnection》 2018年第3期319-329,共11页 全球能源互联网(英文版)
基金 supported by the Tunisian Ministry of High Education and Research under Grant LSE-ENIT-LR11ES15
  • 相关文献

同被引文献41

引证文献4

二级引证文献30

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部