期刊文献+

流动注射在线分离预浓集分光光度法测定环境水样中的痕量铬(Ⅵ) 被引量:3

Determination of trace chromium(Ⅵ) in environmental waters using on-line separation and preconcentration-flow injection spectrophotometry
下载PDF
导出
摘要 利用自制微型离子交换柱 ,采用流动分析技术 ,对含铬 (Ⅵ )环境水样在线自动化分离和预浓集处理 ,联用分光光度检测手段 ,实现了在线自动化样品分离富集及测定。方法的线性范围是 1~ 40ng mL铬 (Ⅵ )。用于测定井水、自来水、电镀液、电镀废液、电镀排放液中的痕量铬 (Ⅵ ) ,回收率在 95 .7%~ 1 0 5 A new method for on-line separation and preconcentration of trace amounts of chromium(Ⅵ) in natural waters and industrial waste waters was developed by using self-made ion-exchange micro-column and flow injection analysis technology. Linear range of determination was (1~40) ng/mL. Samples of natural waters, electroplating liquor, electroplating waste and electroplating effluent were analyzed by the developed procedure with satisfactory results. Recoveries of the method was between 95.7%~105%.
出处 《分析试验室》 CAS CSCD 北大核心 2004年第1期70-72,共3页 Chinese Journal of Analysis Laboratory
基金 河南省教委自然科学基金(1999150 0 3 0 ) 河南省自然科学基金 (0 2 110 2 0 2 0 0 )
关键词 环境水样 铬(Ⅵ) 痕量分析 流动注射 在线分离预浓集 分光光度法 Flow injection Separation and preconcentration Spectrophotometry Chromium(Ⅵ)