期刊文献+

Study of detection times for liver stiffness evaluation by shear wave elastography 被引量:10

Study of detection times for liver stiffness evaluation by shear wave elastography
下载PDF
导出
摘要 AIM: To investigate enough valid measurements (VMs) to assess liver fibrosis in chronic hepatitis B patients (CHB). AIM:To investigate enough valid measurements(VMs)to assess liver fibrosis in chronic hepatitis B patients(CHB).METHODS:One hundred and twelve CHB patients(25women,87 men)with a mean age of 38.43 years received liver stiffness evaluations using real-time shear wave elastography for 10 VMs.All patients underwent liver biopsy.Based on the biopsy pathology,the liver stiffness data obtained from different VMs(1,2,3,5and 10 times)were compared for the evaluation of liver fibrosis.The correlation between the elastic modulus means of the liver obtained from different VMs of detection at each pathological stage was analysed.The receiver operating characteristic(ROC)curve was employed to determine the diagnostic performance of different VMs of detection,and the areas under the ROC curve of different groups were compared.RESULTS:The liver stiffness values obtained from 1 VM,2 VMs,3 VMs,5 VMs and all 10 VMs for stage F0 were 6.95±2.01 kPa,6.87±1.83 kPa,6.90±1.88 kPa,6.95±1.93kPa and 7.15±1.89 kPa,respectively(F=0.043,P=0.996).For stage F1,these values were 7.12±1.72 kPa,7.24±1.72 kPa,7.21±1.74 kPa,7.10±1.78 kPa and7.04±1.70 kPa,respectively(F=0.075,P=0.990).For stage F2,they were 9.37±3.87 kPa,9.18±3.68 kPa,9.19±3.81 kPa,9.18±3.81 kPa and 9.19±3.53 kPa,respectively(F=0.012,P=1.000).For stage F3,these were 11.91±3.88 kPa,11.78±4.04 kPa,11.83±4.07kPa,11.94±4.17 kPa and 12.00±4.02 kPa,respectively(F=0.010,P=1.000).For stage F4,the readings were 19.30±7.63 kPa,19.40±7.36 kPa,19.54±7.43kPa,19.73±7.21 kPa and 20.25±7.22 kPa,respectively(F=0.054,P=0.995).There were no significant differences between these groups.Intraclass correlation coefficients among different pathological stages(F0-F4)with different detection VMs were 0.995,0.993,0.996,0.994 and 0.996,respectively.The mean elasticity values from 1 VM,2 VMs,3 VMs,5 VMs and 10 VMs can accurately distinguish fibrosis stages(F0 vs F1234,F01 vs F234,F012 vs F34 and F0123 vs F4)with no significant differences in the five groups(P>0.05 for all).CONCLUSION:One VM may be sufficient to assess liver fibrosis by using SWE without any significant loss of accuracy in patients with CHB.However,future studies of larger patient samples are necessary for the validation of this method.
出处 《World Journal of Gastroenterology》 SCIE CAS 2014年第28期9578-9584,共7页 世界胃肠病学杂志(英文版)
关键词 Liver stiffness measurement ELASTOGRAPHY Shear wave elastography Non-invasive diagnosis Liver fibrosis Liver stiffness measurement Elastography Shear wav
  • 相关文献

参考文献10

  • 1Schuppan, Detlef,Kim, Yong Ook.Evolving therapies for liver fibrosis[J].Journal of Clinical Investigation.2013(5)
  • 2Emer Fitzpatrick,Alberto Quaglia,Sunitha Vimalesvaran,Maria Sole Basso,Anil Dhawan.Transient Elastography Is a Useful Noninvasive Tool for the Evaluation of Fibrosis in Paediatric Chronic Liver Disease[J].Journal of Pediatric Gastroenterology and Nutrition.2013(1)
  • 3Ke‐Qing Shi,Yu‐Chen Fan,Zhen‐Zhen Pan,Xian‐Feng Lin,Wen‐Yue Liu,Yong‐Ping Chen,Ming‐Hua Zheng.Transient elastography: a meta‐analysis of diagnostic accuracy in evaluation of portal hypertension in chronic liver disease[J].Liver Int.2012(1)
  • 4éric Bavu,Jean-Luc Gennisson,Mathieu Couade,Jeremy Bercoff,Vincent Mallet,Mathias Fink,Anne Badel,Ana?s Vallet-Pichard,Bertrand Nalpas,Micka?l Tanter,Stanislas Pol.Noninvasive In Vivo Liver Fibrosis Evaluation Using Supersonic Shear Imaging: A Clinical Study on 113 Hepatitis C Virus Patients[J].Ultrasound in Medicine & Biology.2011(9)
  • 5S. U.Kim,Y. S.Seo,J. Y.Cheong,M. Y.Kim,J. K.Kim,S. H.Um,S. W.Cho,S. K.Paik,K. S.Lee,K.‐H.Han,S. H.Ahn.Factors that affect the diagnostic accuracy of liver fibrosis measurement by Fibroscan in patients with chronic hepatitis B[J].Alimentary Pharmacology & Therapeutics.2010(3)
  • 6Marie Muller,Jean-Luc Gennisson,Thomas Deffieux,Micka?l Tanter,Mathias Fink.Quantitative Viscoelasticity Mapping of Human Liver Using Supersonic Shear Imaging: Preliminary In Vivo Feasability Study[J].Ultrasound in Medicine & Biology.2009(2)
  • 7Adrien Kettaneh,Patrick Marcellin,Catherine Douvin,Raoul Poupon,Marianne Ziol,Michel Beaugrand,Victor de Lédinghen.Features associated with success rate and performance of fibroscan measurements for the diagnosis of cirrhosis in HCV patients: A prospective study of 935 patients[J].Journal of Hepatology.2006(4)
  • 8Juliette Foucher,Laurent Castéra,Pierre-Henri Bernard,Xavier Adhoute,David Laharie,Julien Bertet,Patrice Couzigou,Victor de Lédinghen.Prevalence and factors associated with failure of liver stiffness measurement using FibroScan in a prospective study of 2114 examinations[J].European Journal of Gastroenterology & Hepatology.2006(4)
  • 9Laurent Castéra,Julien Vergniol,Juliette Foucher,Brigitte Le Bail,Elise Chanteloup,Maud Haaser,Monique Darriet,Patrice Couzigou,Victor de Lédinghen.Prospective comparison of transient elastography, Fibrotest, APRI, and liver biopsy for the assessment of fibrosis in chronic hepatitis C[J].Gastroenterology.2005(2)
  • 10Pierre Bedossa,Delphine Dargère,Valerie Paradis.Sampling variability of liver fibrosis in chronic hepatitis C[J].Hepatology.2003(6)

共引文献16

同被引文献39

引证文献10

二级引证文献141

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部