期刊文献+

Passive-bending,short-type single-balloon enteroscope for endoscopic retrograde cholangiopancreatography in Roux-en-Y anastomosis patients 被引量:3

Passive-bending,short-type single-balloon enteroscope for endoscopic retrograde cholangiopancreatography in Roux-en-Y anastomosis patients
下载PDF
导出
摘要 AIM:To evaluate short-type-single-balloon enteroscope(SBE) with passive-bending,high-force transmission functions for endoscopic retrograde cholangiopancreatography(ERCP) in patients with Roux-en-Y anastomosis.METHODS:Short-type SBE with this technology(SIF-Y0004-V01; working length,1520 mm; channel diameter,3.2 mm) was used to perform 50 ERCP procedures in 37 patients with Roux-en-Y anastomosis.The rate of reaching the blind end,time required to reach the blind end,diagnostic and therapeutic success rates,and procedure time and complications were studied retrospectively and compared with the results of 34 sessions of ERCP performed using a short-type SBE without this technology(SIF-Y0004; working length,1520 mm; channel diameter,3.2 mm) in 25 patients.RESULTS:The rate of reaching the blind end was 90% with SIF-Y0004-V01 and 91% with SIF-Y0004(P = 0.59).The median time required to reach the papilla was significantly shorter with SIF-Y0004-V01 than with SIF-Y0004(16 min vs 24 min,P = 0.04).The diagnostic success rate was 93% with SIFY0004-V01 and 84% with SIF-Y0004(P = 0.17).The therapeutic success rate was 95% with SIF-Y0004-V01 and 96% with SIF-Y0004(P = 0.68).The median procedure time was 40 min with SIF-Y0004-V01 and 36 min with SIF-Y0004(P = 0.50).The incidence of hyperamylasemia was 6.0% in the SIF-Y0004-V01 group and 14.7% in the SIF-Y0004 group(P = 0.723).The incidence of pancreatitis was 0% in the SIFY0004-V01 group and 5.9% in the SIF-Y0004 group(P > 0.999).The incidence of gastrointestinal perforation was 2.0%(1/50) in the SIF-Y0004-V01 group and 2.9%(1/34) in the SIF-Y0004 group(P > 0.999).CONCLUSION:SIF-Y0004-V01 is useful for ERCP inpatients with Roux-en-Y anastomosis and may reduce the time required to reach the blind end. AIM:To evaluate short-type-single-balloon enteroscope(SBE) with passive-bending,high-force transmission functions for endoscopic retrograde cholangiopancreatography(ERCP) in patients with Roux-en-Y anastomosis.METHODS:Short-type SBE with this technology(SIF-Y0004-V01; working length,1520 mm; channel diameter,3.2 mm) was used to perform 50 ERCP procedures in 37 patients with Roux-en-Y anastomosis.The rate of reaching the blind end,time required to reach the blind end,diagnostic and therapeutic success rates,and procedure time and complications were studied retrospectively and compared with the results of 34 sessions of ERCP performed using a short-type SBE without this technology(SIF-Y0004; working length,1520 mm; channel diameter,3.2 mm) in 25 patients.RESULTS:The rate of reaching the blind end was 90% with SIF-Y0004-V01 and 91% with SIF-Y0004(P = 0.59).The median time required to reach the papilla was significantly shorter with SIF-Y0004-V01 than with SIF-Y0004(16 min vs 24 min,P = 0.04).The diagnostic success rate was 93% with SIFY0004-V01 and 84% with SIF-Y0004(P = 0.17).The therapeutic success rate was 95% with SIF-Y0004-V01 and 96% with SIF-Y0004(P = 0.68).The median procedure time was 40 min with SIF-Y0004-V01 and 36 min with SIF-Y0004(P = 0.50).The incidence of hyperamylasemia was 6.0% in the SIF-Y0004-V01 group and 14.7% in the SIF-Y0004 group(P = 0.723).The incidence of pancreatitis was 0% in the SIFY0004-V01 group and 5.9% in the SIF-Y0004 group(P > 0.999).The incidence of gastrointestinal perforation was 2.0%(1/50) in the SIF-Y0004-V01 group and 2.9%(1/34) in the SIF-Y0004 group(P > 0.999).CONCLUSION:SIF-Y0004-V01 is useful for ERCP inpatients with Roux-en-Y anastomosis and may reduce the time required to reach the blind end.
出处 《World Journal of Gastroenterology》 SCIE CAS 2015年第5期1546-1553,共8页 世界胃肠病学杂志(英文版)
关键词 PASSIVE bending ROUX-EN-Y ANASTOMOSIS Endoscopic r Passive bending Roux-en-Y anastomosis Endoscopic r
  • 相关文献

参考文献17

  • 1M. Shimatani,M. Matsushita,M. Takaoka,M. Koyabu,T. Ikeura,K. Kato,T. Fukui,K. Uchida,K. Okazaki.Effective ”short” double-balloon enteroscope for diagnostic and therapeutic ERCP in patients with altered gastrointestinal anatomy: a large case series[J]. Endoscopy . 2009 (10)
  • 2A. Saleem,T. Baron,C. Gostout,M. Topazian,M. Levy,B. Petersen,L. Wong Kee Song.Endoscopic retrograde cholangiopancreatography using a single-balloon enteroscope in patients with altered Roux-en-Y anatomy[J]. Endoscopy . 2010 (08)
  • 3Andrew Y. Wang,Bryan G. Sauer,Brian W. Behm,Madhuri Ramanath,Dawn G. Cox,Kristi L. Ellen,Vanessa M. Shami,Michel Kahaleh.Single-balloon enteroscopy effectively enables diagnostic and therapeutic retrograde cholangiography in patients with surgically altered anatomy[J]. Gastrointestinal Endoscopy . 2010 (3)
  • 4Yutaka Saito,Hidenobu Kimura.RESPONSIVE INSERTION TECHNOLOGY. Digestive Endoscopy . 2011
  • 5S. Zepeda-Gómez,R. Barreto-Zu?iga,S. Ponce-de-León,A. Meixueiro-Daza,J. Herrera-López,J. Camacho,F. Tellez-Avila,F. Valdovinos-Andraca,F. Vargas-Vorackova.Risk of hyperamylasemia and acute pancreatitis after double-balloon enteroscopy: a prospective study[J]. Endoscopy . 2011 (09)
  • 6Takashi Obana,Naotaka Fujita,Kei Ito,Yutaka Noda,Go Kobayashi,Jun Horaguchi,Shinsuke Koshita,Yoshihide Kanno,Takahisa Ogawa,Shinichi Hashimoto,Kaori Masu.Therapeutic endoscopic retrograde cholangiography using a single‐balloon enteroscope in patients with R oux‐en‐ Y anastomosis[J]. Digestive Endoscopy . 2013 (6)
  • 7Haruta Hidenori,Yamamoto Hironori,Mizuta Koichi,Kita Yoshiaki,Uno Takeji,Egami Satoshi,Hishikawa Shuji,Sugano Kentaro,Kawarasaki Hideo.A case of successful enteroscopic balloon dilation for late anastomotic stricture of choledochojejunostomy after living donor liver transplantation. Liver transplantation : official publication of the American Association for the Study of Liver Diseases and the International Liver Transplantation Society . 2005
  • 8L. Aabakken,M. Bretthauer,P. Line.Double-balloon enteroscopy for endoscopic retrograde cholangiography in patients with a Roux-en-Y anastomosis[J]. Endoscopy . 2007 (12)
  • 9K. Sato,S. Ito,F. Shigiyama,T. Kitagawa,K. Hirahata,K. Tominaga,I. Maetani.A prospective randomized study on the benefits of a new small-caliber colonoscope[J]. Endoscopy . 2012 (08)
  • 10Therapeutic ERCP with the double-balloon enteroscope in patients with Roux-en-Y anastomosis[J]. Gastrointestinal Endoscopy . 2008 (6)