摘要 AIM: To identify whether the forceps estimation is more useful than visual estimation in the measurement of colon polyp size.METHODS: We recorded colonoscopy video clips that included scenes visualizing the polyp and scenes using open biopsy forceps in association with the polyp, which were used for an exam. A total of 40 endoscopists from the Busan Ulsan Gyeongnam Intestinal Study Group Society(BIGS) participated in this study. Participants watched 40 pairs of video clips of the scenes for visual estimation and forceps estimation, and wrote down the estimated polyp size on the exam paper. When analyzing the results of the exam, we assessed interobserver differences, diagnostic accuracy, and error range in the measurement of the polyp size.R E S U LT S : The overall intra-class correlation coefficients(ICC) of inter-observer agreement for forceps estimation and visual estimation were 0.804(95%CI: 0.731-0.873, P < 0.001) and 0.743(95%CI: 0.656-0.828, P < 0.001), respectively. The ICCs of each group for forceps estimation were higher than those for visual estimation(Beginner group, 0.761 vs 0.693; Expert group, 0.887 vs 0.840, respectively). The overall diagnostic accuracy for visual estimation was 0.639 and for forceps estimation was 0.754(P < 0.001). In the beginner group and the expert group, the diagnostic accuracy for the forceps estimation was significantly higher than that of the visual estimation(Beginner group, 0.734 vs 0.613, P < 0.001; Expert group, 0.784 vs 0.680, P < 0.001, respectively). The overall error range for visual estimation and forceps estimation were 1.48 ± 1.18 and 1.20 ± 1.10, respectively(P < 0.001). The error ranges of each group for forceps estimation were significantly smaller than those for visual estimation(Beginner group, 1.38 ± 1.08 vs 1.68 ± 1.30, P < 0.001; Expert group, 1.12 ± 1.11 vs 1.42 ± 1.11, P < 0.001, respectively).CONCLUSION: Application of the open biopsy forceps method when measuring colon polyp size could help reduce inter-observer differences and error rates. AIM: To identify whether the forceps estimation is more useful than visual estimation in the measurement of colon polyp size.METHODS: We recorded colonoscopy video clips that included scenes visualizing the polyp and scenes using open biopsy forceps in association with the polyp, which were used for an exam. A total of 40 endoscopists from the Busan Ulsan Gyeongnam Intestinal Study Group Society (BIGS) participated in this study. Participants watched 40 pairs of video clips of the scenes for visual estimation and forceps estimation, and wrote down the estimated polyp size on the exam paper. When analyzing the results of the exam, we assessed inter-observer differences, diagnostic accuracy, and error range in the measurement of the polyp size.RESULTS: The overall intra-class correlation coefficients (ICC) of inter-observer agreement for forceps estimation and visual estimation were 0.804 (95%CI: 0.731-0.873, P &#x0003c; 0.001) and 0.743 (95%CI: 0.656-0.828, P &#x0003c; 0.001), respectively. The ICCs of each group for forceps estimation were higher than those for visual estimation (Beginner group, 0.761 vs 0.693; Expert group, 0.887 vs 0.840, respectively). The overall diagnostic accuracy for visual estimation was 0.639 and for forceps estimation was 0.754 (P &#x0003c; 0.001). In the beginner group and the expert group, the diagnostic accuracy for the forceps estimation was significantly higher than that of the visual estimation (Beginner group, 0.734 vs 0.613, P &#x0003c; 0.001; Expert group, 0.784 vs 0.680, P &#x0003c; 0.001, respectively). The overall error range for visual estimation and forceps estimation were 1.48 &#x000b1; 1.18 and 1.20 &#x000b1; 1.10, respectively (P &#x0003c; 0.001). The error ranges of each group for forceps estimation were significantly smaller than those for visual estimation (Beginner group, 1.38 &#x000b1; 1.08 vs 1.68 &#x000b1; 1.30, P &#x0003c; 0.001; Expert group, 1.12 &#x000b1; 1.11 vs 1.42 &#x000b1; 1.11, P &#x0003c; 0.001, respectively).CONCLUSION: Application of the open biopsy forceps method when measuring colon polyp size could help reduce inter-observer differences and error rates.
出处 《World Journal of Gastroenterology》 SCIE CAS 2016年第11期3220-3226,共7页 世界胃肠病学杂志(英文版)
关键词 COLON POLYP COLONOSCOPY Measurement ENDOSCOPY Colon polyp Colonoscopy Measurement Endoscopy
  • 相关文献

参考文献32

  • 1Winawer S J,Zauber A G,Ho M N,O’Brien M J,Gottlieb L S,Sternberg S S,Waye J D,Schapiro M,Bond J H,Panish J F.Prevention of colorectal cancer by colonoscopic polypectomy. The National Polyp Study Workgroup. The New England Quarterly . 1993
  • 2Yoon Jung,Jung Park,Hong Kim,Yong Cho,Chong Sohn,Woo Jeon,Byung Kim,Jin Sohn,Dong Park.Complete biopsy resection of diminutive polyps[J].Endoscopy.2013
  • 3David G. Hewett.??Colonoscopic polypectomy: current techniques and controversies(J)Gastroenterology Clinics of North America . 2013
  • 4Vanessa Cottet,Valérie Jooste,Isabelle Fournel,Anne-Marie Bouvier,Jean Faivre,Claire Bonithon-Kopp.Long-term risk of colorectal cancer after adenoma removal: a population-based cohort study[J]. Gut . 2012 (8)
  • 5Yil Sik Hyun,Dong Soo Han,Joong Ho Bae,Hye Sun Park,Chang Soo Eun.??Graduated injection needles and snares for polypectomy are useful for measuring colorectal polyp size(J)Digestive and Liver Disease . 2011 (5)
  • 6Chi-Yang Chang,Han-Mo Chiu,Hsiu-Po Wang,Ching-Tai Lee,John Jen Tai,Chia-Hung Tu,Chi-Ming Tai,Tsung-Hsien Chiang,Jason Kunming Huang,Dun-Cheng Chang,Jaw-Town Lin.??An endoscopic training model to improve accuracy of colonic polyp size measurement(J)International Journal of Colorectal Disease . 2010 (5)
  • 7David Lieberman,Matthew Moravec,Jennifer Holub,Leann Michaels,Glenn Eisen.Polyp Size and Advanced Histology in Patients Undergoing Colonoscopy Screening: Implications for CT Colonography[J].Gastroenterology.2008(4)
  • 8Douglas J. Robertson,E. Robert Greenberg,Michael Beach,Robert S. Sandler,Dennis Ahnen,Robert W. Haile,Carol A. Burke,Dale C. Snover,Robert S. Bresalier,Gail McKeown-Eyssen,Jack S. Mandel,John H. Bond,Rosalind U. van Stolk,Robert W. Summers,Richard Rothstein,Timothy R. Church,Bernard F. Cole,Tim Byers,Leila Mott,John A. Baron.Colorectal Cancer in Patients Under Close Colonoscopic Surveillance[J]. Gastroenterology . 2005 (1)
  • 9Navjot Singh,Matthew Harrison,Douglas K. Rex.??A survey of colonoscopic polypectomy practices among clinical gastroenterologists(J)Gastrointestinal Endoscopy . 2004 (3)
  • 10AHMED M. LOTFI,ROBERT J. SPENCER,DUANE M. ILSTRUP,L. JOSEPH MELTON.Colorectal Polyps and the Risk of Subsequent Carcinoma. Mayo Clinic Proceedings . 1986

共引文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部