目的建立溶剂解吸毛细管气相色谱法同时测定工作场所空气中11种烷烃和卤代烃的测定方法。方法样品经活性炭管采集后,二硫化碳溶剂解吸,经毛细管色谱柱HP-INNOWAX分离,氢火焰离子化检测器检测,保留时间定性,外标法定量。结果 11种烃类化合物线性关系良好,相关系数均大于0.999 0,检出限和定量下限分别为0.14~2.42 mg/L和0.47~8.06mg/L,最低检出浓度和最低定量浓度分别为0.02~8.06 mg/m3和0.08~1.34 mg/m3 (以采集6.0 L空气计);平均解吸效率为85.94%~95.85%,批内、批间精密度分别为0.04%~7.08%和0.09%~8.04%,样品在常温下至少可保存14天。结论该方法准确度高,灵敏快速,检出限低,适合于工作场所空气中11种烃类化合物的同时测定。
[Objective]To establish a method for simultaneous determination of 11 kinds of alkanes and halogenated hydrocarbons in workplace air by solvent desorption-gas chromatography.[Methods]The samples were enriched by activated charcoal tub,and then desorbed with carbon disulfide.The target compounds were separated by HP-INNOWAX capillary column and detected by hydrogen flame ionization detector,qualitatived by retention time and qualified by the matrix-matched external standard method.[Results]Good linearity of the 11 kinds of hydrocarbon compounds was found,and the correlation coefficients were above 0.999 0.The limit of detection and the limit of quantification were 0.14-2.42 mg/L and 0.47-8.06 mg/L respectively.The minimum detectable concentration and the minimum quantification concentration were 0.02-8.06 mg/m3 and 0.08-1.34 mg/m3 respectively(sample volume of 6.0 L).The average desorption efficiency was 85.94%-95.85%.The within-run and between-run precisions were 0.04%-7.08%and 0.09%-8.04%,respectively.The samples could be kept at least 14 days under normal temperature.[Conclusion]This method is highly efficient,accurate and sensitive,with low detection limit.It is suitable for the simultaneous determination of 11 kinds of hydrocarbon organic compounds in workplace air.
作者
周常侠
彭建梅
叶立和
蔡小璇
ZHOU Chang-xia;PENG Jian-mei;YE Li-he;CAI Xiao-xuan(Physical and Chemical Laboratory of Dongguan Prevention and Treatment Center for Occupational Disease,Dongguan Guangdong,523008,China)
出处
《职业与健康》
CAS
2019年第7期904-907,共4页
Occupation and Health
基金
东莞市社会科技发展(重点)项目(201850715005929)
关键词
烷烃
卤代烃
气相色谱
工作场所
Alkanes
Halogenated hydrocarbons
Gas chromatography
Workplace air