摘要
[目的]基于硝酸银比色法建立一种准确、简易可行的硫化氢现场半定量检测方法。[方法]在采样点用一支装有10.0 mL硫化氢吸收液的多孔玻板吸收管,以0.5 L/min流量采集5 min空气样品。现场取5.0 mL吸收液用硝酸银显色剂快速显色,与阳性对照试剂和阴性对照试剂进行目视比色。[结果]方法的半定量结果准确,最低检出浓度为1.6 mg/m3,相对标准偏差为3.2%。常见的无机阴离子对结果不产生干扰。[结论]本方法经济成本低,简易可行,现场测定结果与实验室检测结果量值溯源统一,适用于隐匿性硫化氢的现场调查。
[Objective]To establish a simply practicable semi-quantitative detection method of hydrogen sulfide based on silver nitrate colorimetry.[Methods]At the sampling site,a multi-hole absorbing tube containing 10.0 mL hydrogen sulfide absorbing solution was used to collect air sample for 5 minutes at 0.5 L/min sampling flow.Then,5.0 mL absorbing solution was rapidly colored with silver nitrate and the color was visual colorimetric determined,compared with both positive and negative control reagent.[Results]The method showed that the semi-quantitative determination results were accurate,with detection limit 1.6 mg/m3 and relative standard deviation(RSD)3.2%.The common inorganic anions had no interference.[Conclusion]This method is low cost,convenient,simple,and applicable for the investigation of hidden hydrogen sulfide.
作者
庄小舟
彭建梅
叶立和
蔡小璇
张凤华
钟苑琴
ZHUANG Xiaozhou;PENG Jianmei;YE Lihe;CAI Xiaoxuan;ZHANG Fenghua;ZHONG Yuanqin(Dongguan Center for Occupational Diseases Control and Prevention,Dongguan,Guangdong 523008,China)
出处
《职业卫生与应急救援》
2019年第3期283-286,共4页
Occupational Health and Emergency Rescue
基金
东莞市社会科技发展(重点)项目(2018507150051626)
关键词
气体中毒
硫化氢
硝酸银比色法
半定量检测
实际应用
gas poisoning
hydrogen sulfide
silver nitrate colorimetry
semi-quantitative detection
practical application