摘要
论述了用霍尔元件检测无功功率的方法.用过零触发方式触发可控硅开关投、切电容器组,对无功功率进行适时、合理有效的补偿。
The method for the measuring the reactive power by Holeelement is introduced in this paper.To compensated effectively and intime the ractive power,the authors use the switch of SCR at zero-position triggering to control the group of capacitor on or off.
出处
《湘潭大学自然科学学报》
CAS
CSCD
1992年第1期118-122,共5页
Natural Science Journal of Xiangtan University
关键词
动态
无功功率
自动补偿装置
dynamical reactive power
frigger at zeio-position
voltage detecting
logic control