对酸碱滴定中指示剂参与的滴定终点过程进行了研究.对常规滴定终点误差进行了分析,得到滴定实际状况的终点误差计算公式,并给出了提高分析结果准确度的途径,并认为校正终点是提高分析结果准确度的可行且易于操作的方法.
In this paper the end point process with the participation of indicator is studied. As a result, the end point error formula is obtained, and the revisal and point is considered as the best way to get good accuracy of experimental results in acid-base titrations.