结合工程实例 ,针对自立式钢管塔结构的基桩与桩帽的连接部位的极限承载力进行了验算 ,并在实际工程中得到成功的应用。
Verification of the ultimate bearing capacity between foundation piles and pile caps for isolated steel pipe towers was made in conjunction with practical engineering works and the results of the verification were successfully used in an engineering project.The author presents his own views on the major factors which should be considered during the design of similar projects