摘要
报道一种新的自行设计研制的磁偶合驱动轴流式血泵 ,电机采用自制的中空无刷直流电机 ,血泵进出口及叶轮在一条轴线上 ,使血泵内与流体力学有关的结构更为合理 ,对血泵性能进行了测试和验证 ,实验表明该泵的性能良好 。
A new-designed axial flow blood pump, dived by magnetic coupling and using internal hollow brushless DC motor and inlet and outlet in line with impeller, was tested in mimic circuit. The results showed good performance of the new pump and indicated that its hydrodynamic characteristic can meet the demands of clinical extracorporeal circulation and auxiliary circulation.
出处
《生物医学工程学杂志》
EI
CAS
CSCD
2004年第1期131-133,共3页
Journal of Biomedical Engineering