摘要
针对N12 5机组频繁参与调峰运行的状况 ,主要介绍调峰机组低负荷运行的能损有关参数如主蒸汽流量的迭代初值、汽轮机各抽汽压力、排汽压力、相对内效率 。
Directing against the situation of N125 unit frequently participating in peakload regulation, an energy loss monitoring system adapting to operating condition variation of the unit has been developed and created. The determination of target value of relevant parameters for energy loss under low load operation of the peakload regulating unit, as well as the design of related mathematic model have been mainly presented.
出处
《热力发电》
CAS
北大核心
2004年第2期14-16,共3页
Thermal Power Generation