摘要
目的 研究自创多腔一体式输卵管再通器在临床中应用的价值。方法 380例输卵管阻塞所致不孕患者应用自创的输卵管再通器 ,行选择性输卵管造影和介入再通术。结果 发现 70 8条输卵管阻塞 ,疏通 6 78条 ,再通率95 .8% (6 78/70 8) ,怀孕率 4 7.4 % (180 /380 ) ,无严重并发症。结论 输卵管再通术中应用该自创输卵管再通器是安全。
Objective To study the use of self-made multiluminal fallopian tube catheter during clinical practice. Methods Three hundred and eighty women (aged 22~41 yr,mean 28 yr) with infertility were treated with the catheter and selective fallopian tube catheterization and recanalization were performed. Results Of the obstructed 708 fallopian tube 608 tubes were deoppilated, the recanalization rate was 95.7 %(678/708). The gestation rate was 47.2 %(180/380). Any serious complication was not found. Conclusion It demonstrates the self-made catheter is safe and highly effictive in recanalization fallopian tube.
出处
《生物医学工程与临床》
CAS
2003年第1期34-36,共3页
Biomedical Engineering and Clinical Medicine
关键词
不育症
输卵管再通器
介入治疗
输卵管阻塞
infertility
fallopian tube recanalization
interventional therapy
fallopian tube obstruction