摘要 释光测年实验室照明光源的特征(波长与功率)直接影响到释光测年数据的准确性,因此释光测年技术对照明光源的要求很严格。通过对比,选择了典型的红光固体二极管R LED1(661±15)nm作为研究对象。利用R LED1点阵对已知剂量的石英和钾长石样品进行不同时间的光照后,再用单片再生法恢复样品的等效剂量,发现样品的等效剂量与已知剂量差别不大,表明石英和钾长石经过不同时间的R LED1点阵光照后没有发生明显的信号衰减,对测年样品没有影响。因此,利用波长为(661±15)nm的红光固体二极管作为释光测年实验室的照明光源是安全可靠的。 The choice of lighting is very vital for luminescence dating laboratory. Based on the bleaching of different wavelengths of quartz and feldspar, R-LED1 ( 661 15 nm ) was selected from three types of red LED ( R-LED1, R-LED2 and R-LED3 ) for its waveband and lighting intensity. To estimate the safety of R-LED1 array lighting, dose recovery test using single-aliquot regenerative-dose protocol was applied to the quartz and K-feldspar after exposure for different times to R-LED1 array lighting. The recovery doses showed that there was no obvious effect after exposure to R-LED1 array. Contrasting to the low-pressure sodium vapor lamp, R-LED1 array is safe for luminescence dating laboratory, and more convenient, cheaper for use. So R-LED1 array is an ideal lighting for luminescence dating laboratory.
出处 《海洋地质与第四纪地质》 CAS CSCD 北大核心 2004年第1期133-137,共5页 Marine Geology & Quaternary Geology
基金 黄土与第四纪国家重点实验室基金(SKLLQ0317)
关键词 ?红光固体二极管 单片再生法 光照 晒退 测年 red LED array SAR protocol lighting bleaching
  • 相关文献

参考文献11

  • 1[1]Prescott J R,Robertson G B. Sediment dating by luminescence: a review [J]. Radiation measurements, 1997, 27: 893-922.
  • 2[2]Lu Y C, Zhao H, Ying G M, et al. Luminescence dating of loess-paleosol sequences in the past about 100 ka in North China [J]. Bulletin of the national museum of Japanese history, 1999, 81: 209-220.
  • 3[3]Huntley D J,Baril M R. Yet another note on laboratory lighting [J]. Ancient TL, 2002, 20: 39-40.
  • 4[4]Spooner N A, Questiaux D G,Aitken M J. The use of sodium lamps for low-intensity laboratory safe lighting for optical dating [J]. Ancient TL, 2000, 18: 45-49.
  • 5[5]Krbetschet M R, Gotze J, Dietrich A,Trautmann T. Spectral information from minerals relevant for luminescence dating [J]. Radiation measurements, 1997, 27: 695-748.
  • 6[6]Wintle A G. Luminescence dating: laboratory procedures and protocols [J]. Radiation measurements [J], 1997, 27: 769-817.
  • 7[7]Murray A S, Wintle A G. Luminescence dating of quartz using an improved single-aliquot regenerative-dose protocol [J]. Radiation measurements, 2000, 32: 57-73.
  • 8[8]Murray A S, Wintle A G. The single aliquot regenerative dose protocol: potential for improvements in reliability [J]. Radiation measurements, 2003, 37: 377-381.
  • 9[9]Banerjee D, Murray A S, Botter-Jensen L, Land L. Equivalent dose estimation using a single aliquot of polymineral fine grains [J]. Radiation measurements, 2001, 33: 73-94.
  • 10[10]Wintle A G. Anomalous fading of thermoluminescence in mineral samples [J]. Nature, 1973, 245: 143-144.

同被引文献459

引证文献22

二级引证文献110

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部