期刊文献+

电子线旋转治疗技术在乳腺癌术后胸壁照射中的应用 被引量:3

Electron Arc Therapy:Application of Chest Wall Irradiation after Mastectomy
下载PDF
导出
摘要 随着肿瘤综合治疗的不断发展,乳腺癌的治疗策略发生了很大变化。但放射治疗作为一种局部治疗方法在乳腺癌综合治疗中仍占重要地位。乳腺癌术后胸壁复发占所有局部复发的44%~69%,居第一位,成为乳腺癌术后放射治疗的最重要靶区。然而,由于胸廓特殊的几何形状,传统的照射方法难以达到合理的剂量分布。电子线旋转治疗技术利用电子线的剂量分布特点、结合胸壁的形状和靶区的深度选择不同的能量,使靶区达到合理的剂量分布,同时降低心、肺受量,在胸壁照射中具有较大的优势。临床实践也证实,电子线旋转照射与常规照射技术相比具有局部控制率高、心肺毒性小、皮肤反应轻等优点,在胸壁照射中具有较高的临床应用价值。 With the development of multidisciplinary treatment for cancer, gre at changes have taken place in the therapeutic strategy of breast cancer. Howeve r, radiotherapy as a method of local management, still plays an important role i n the combined treatment of breast cancer. The recurrence in the chest wall rank s the first, accounting for 44-69% of the total local-regional relapse, ther efore, the chest wall is commonly regarded as the most important target of radio therapy after mastectomy. The traditional irradiation techniques cannot reach an ideal dose distribution due to the irregular shape of the chest wall. Electron arc therapy, by using the electron characteristics of dose distribution, combini ng the shape of thorax and the depth of target volume, make the dose distributio n of target volume more reasonable, decreases the dose of heart or lung and has more clinical benefit than traditional techniques. On the other hand, it had bee n demonstrated by some clinical research that irradiation with electron arc coul d provide a high rate of local control and generally acceptable acute and long- term toxicity, comparing with the traditional irradiation techniques.
出处 《癌症》 SCIE CAS CSCD 北大核心 2004年第3期358-360,共3页 Chinese Journal of Cancer
关键词 电子线旋转 治疗技术 乳腺癌术 胸壁照射 肿瘤 Breast neoplasms Radiotherapy Electron arc therapy
  • 相关文献

参考文献11

  • 1惠周光,余子豪.早期乳腺癌根治术或改良根治术后的放射治疗[J].中华放射肿瘤学杂志,2001,10(1):62-64. 被引量:24
  • 2Swedborg I, Wallgren A. The effect of pre- and postoperative radiotherapy on the degree of edema, shoulder-joint mobility and gripping force [J]. Cancer,1981, 47:877-881.
  • 3Larson D, Weinstein M, Goldberg I, et al. Edema of the arm as a fuction of the extent of axillary sugery in patients with stage Ⅰ-Ⅱ carcinoma of the breast treated with primary radiotheraoy [J].lnt J Radiation Oncology Biol Phys,1986, 12:1575-1582.
  • 4Leonard C, Corkill M, Tompkin J, et al. Are axill ary recurrence and over allsurvival affected by axillary extension in breast cancer? lmpication for radiation therapy [J]. J Clin Oncol, 1995, 13:47-53.
  • 5Gaffney DK, Prows J, Leavitt DD, et al. Electron arc irradiation of the postmastectomy chest wall: clinical results [J]. Radiother Oncol, 1997, 42(1): 17-24.
  • 6Gaffney DK, Leavitt DD, Tsodikov A,et al. Electron arc irradiation of the postmastectomy chest wall with CT treatment planning: 20-year experience[J]. Int J Radiation Oncology Biol Phvs, 2001,51:994-1001.
  • 7Gaffney DK, Lee CM, Leavitt DD, et al. Electron arc irradiation of the postmastectomy chest wall in locally recurrent and metastatic breast cancer[J]. Am J Clin Oncol, 2003, 26(3):241-246.
  • 8Meneely LK, Leavitt DD, Egger M J, et al. Dose volume histogram analsis of lung radiation from chest wall treatment: Comparison of electron are and tangential photon beam techniques [J]. Int J Radiation Oncology Biol Phvs, 1991, 21:515-520.
  • 9Peacock LM, Leavitt DD, Gibbs FA Jr,et al. Electron arc therapy: Clinical experience with chest wall irradiation[J]. Int J Radiation Oncology Biol Phys, 1984, 10: 2149-2153.
  • 10Mcneely LK, Jacobson GM, Leavitt DD, et al. Electron arc therapy: Chest wall irradiation of breast cancer patients[J]. Int J Radiation Oncology Biol Phys, 1988, 14:1287-1294.

二级参考文献6

共引文献23

同被引文献30

  • 1陈立新,卢杰,梁健,黄劭敏,祁振宇,钱剑扬.全身皮肤电子束照射剂量学参数的测量和讨论[J].中华放射肿瘤学杂志,2005,14(4):331-334. 被引量:3
  • 2张晶,曲强.电子束矩形照射野输出因子的探讨[J].医疗设备信息,2005,20(8):66-66. 被引量:1
  • 3曾自力.空气间隙对电子束吸收剂量的影响[J].中国辐射卫生,2006,15(4):465-465. 被引量:2
  • 4D. Gaffney, D. Leavitt, A. Tsodikov, et al. Electron arc irradiation of the postmastectomy chest wall with CT treatment planning: 20-year experience [J]. International Journal Of Radiation Oncology. Biology. Physics. 2001, 51(4):994-1001.
  • 5T. Hehr, J. Classenl, M. Huth, L Durst,et al. Postmastectomy Radiotherapy of the Chest Wall- Comparison of Electron-Rotation Technique and Common Tangential Photon Fields [J]. Strahlentherapie und Onkologie. 2004, 180(10):629-636.
  • 6J Herzen, M Todorovic, F Cremers, et al. Dosimetric evaluation of a 2D pixel ionization chamber for implementation in clinical routine. Physics in Medicine and Biology [J]. 2007, 52(4): 1197-1208.
  • 7B Arjomandy, N Sahoo, X Ding, et al. Use of a 2-dimensional ionization chamber array for proton therapy beam quality assurance [J]. Medical. Physics. 2008, 35(9) :3889-3894.
  • 8Khan FM, Doppke KP, Hogstrom KP, et al. Clinical electron beam dosimetry: report of AAPM radiation therapy committee task group No. 25 [J]. Med Phys, 1991,18 ( 1 ) : 73 - 109.
  • 9IAEA ( International Atomic Energy Agency ). The use of plant parallel ionization chambers in high energy electron and photon beams[ P]. An International Code of Practice Technical Report Series no 277 ( Vienna: IAEA ), 1997.
  • 10Davies G, Bidmead M, Lamb C, et al. Electron dosimetry of angular fields [ J ]. Br J Radiol, 2007,80 (2) : 202 - 208.