摘要
在电场断面面积为 0 .3 m2 (60 0 m× 50 0 m)的电除尘器 (ESP)实验系统上 ,采用正交试验法 ,确定电晕线型式、含尘浓度、电压值和风量 (电场风速 ) 4个试验因子 ,总除尘效率为指标值 ,进行电除尘器对烧结灰除尘性能的试验研究。研究结果表明 ,当气流含尘浓度从1 5g/ m3提高到 2 5g/ m3时 ,ESP的总除尘效率 η从 96.87%降至 87.55% ;当电源电压值由 85k V增至 96k V后 ,ESP的总除尘效率从98.1 6%降至 87.55% ;当 ESP的电场风速由 0 .62 m/ s增至 0 .79m/ s,总除尘效率由 96.87%降至 92 .46% ;星型线 ESP的除尘效率相对较低 ;尖端放电可改善 ESP用于高比电阻粉尘时的操作性能 ,芒刺线、锯齿线 ESP的除尘效率分别高达 99.46%和 99.55%。
The paper aims to improve the collection efficiency of Electrostatic Precipitators (ESP) with 0.3 m^2 electrical field area for sintering dust. The author has adopted a method of vertical test in determining the data concerned, such as the type of electrode, the dust concentration, power source voltage as well as the gas velocity for his experimental factors as the index values. The test results indicate that high dust concentration may lead to corona discharge block. And, as a result, the ESP collection efficiency may decrease from 96.87% to 87.55% on the condition that the dust concentration rises from 15 g/m^3 to 25 g/m^3. However, when the power source voltage increases from 85 kV to 96 kV,the ESP collection efficiency will decrease from 98.16% to 87.55%. But, if dust resistivity increases, the spiked emitter type electrodes may improve the ESP operation.
出处
《安全与环境学报》
CAS
CSCD
2004年第1期49-51,共3页
Journal of Safety and Environment
关键词
环境工程
电除尘器
电晕闭塞
除尘效率
environmental engineering
electrostatic precipitators
corona discharge block
collection efficiency