期刊文献+

聚乙二醇电解质散中氯化钾、碳酸氢钠的含量测定

Assay for KCI and NaHCO_3 in Macrogol Electrolytes Powder
下载PDF
导出
摘要 目的 建立测定聚乙二醇电解质散中氯化钾和碳酸氢钠混合物含量的方法。方法 二步滴定法。先用0.1 mol/L盐酸滴定液滴定碳酸氢钠,再用0.1 mol/L硝酸银滴定液滴定氯化钾的二步滴定法。结果 以检验量的80%、100%、120%取样,进行试验,碳酸氢钠和氯化钾的平均回收率分别为99.92%(RSD=O.15%)和99.53%(RSD=0.45%)。精密度试验,RSD分别为0.11%和0.36%(n=8)。结论 本方法是一种新的氯化钾、碳酸氢钠混合物的含量测定方法,简便、经济、实用。 Objective To establish a method to determine the content of KC1 and NaHCO3 in Macrogol Electrolytes Powder. Methods Twi-titration assay was used. To titrate NaHCO3 with 0.1 mol/L hydrochloric acid VS firstly and then , to titrate KC1 with 0.1 mol/ L silver nitrate VS. Results On the basis the examination quantity of 80% , 100% , 120% ,The average recovery rate of KC1 and NaHCO3 were 99.92% ( RSD=0.15%) and 99.53%( RSD=0.45%), the precision were 0.11% and 0. 36% (n=8). Conclusion This method is a new way for assay of mixture KCl and NaHCO3. It is sinple, cost, saving and practical.
作者 王曼熙
出处 《广东药学》 2004年第1期13-14,共2页 Guangdong Pharmaceutical Journal
关键词 聚乙二醇电解质散 二步滴定法 氯化钾 碳酸氢钠 含量测定 Macrogol Electrolytes Powder twi-titration assay KCl NaHCO3 assay
  • 相关文献

参考文献2

  • 1国家药典委员会.中国药典(二部)[S].北京:化学工业出版社,2000.248.
  • 2许瑞庭编著 严济祥审阅.实用药物分析化学[M].杭州:浙江科学技术出版社,2000.154,251,252,251.

共引文献41

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部