摘要
介绍一种用于铁矿中铁含量测定的微量滴定方法.该法采用WD-COⅡ型微量滴定管(中国专利ZL00230756.1),以K2Cr2O7为滴定剂,采用甲基橙指示剂代替有毒试剂HgCl2,指示预处理完全程度和除去过量的还原剂Sn2+,该法使分析速度加快,试剂耗量减少,且与常量滴定法结果一致.
The micro-titration,it was applied to determine the iron content of iron ore. the iron ore was dissolved in HCl, then was treated with Sn^(2+). Methyl orange was used as indicatior in the prereduction of Fe(Ⅲ) and to eliminated the extra proeductant Sn^(2+).The resulting Fe(Ⅱ)was titrated with K_2Cr_2O_7 solution and dipherylamine sulfonic sodium as imdicator.The titration results were well in accordance with that obtained by normal titrimetry.However, This method showed some advantage over the normal one.
出处
《内蒙古民族大学学报(自然科学版)》
2004年第1期38-40,共3页
Journal of Inner Mongolia Minzu University:Natural Sciences