期刊文献+

W型火焰锅炉冷态试验及空气动力场数值模拟 被引量:1

Cold Test and Numerical Simulation of Aerodynamic Field of W-Flame Boiler
下载PDF
导出
摘要 对 DG1 0 2 5 /1 8.2 - 1 4型 W火焰锅炉在冷态下进行了全面的测试分析 ,并掌握了锅炉的各种特性 ;在此基础上对一次风和二次配风进行了冷态调平 ,为锅炉运行调整提供了可靠的依据。同时 ,对炉内空气动力场进行了飘带试验研究和计算机数值模拟研究 ,结果表明 :经过合理的一、二次风配置 。 The characteristics of the DG1025/18.2-Ⅱ14 W-flame boiler were obtained based on cold test. By balancing the distribution of primary air and second air along the width direction of the boiler hearth,the credible references were given for boiler operation.The aerodynamic field inside the boiler was investigated based on the tie-floating test and numerical simulation. The results show that good aerodynamic field can be obtained after distributing the primary air and second air reasonably.
出处 《湖南电力》 2004年第1期9-11,15,共4页 Hunan Electric Power
关键词 W型火焰锅炉 冷态试验 空气动力场 数值模拟 DG1025/18.2-Ⅱ14型 空气预热器 制粉系统 W-flame boiler cold test aerodynamic field numerical simulation
  • 相关文献

参考文献2

二级参考文献3

共引文献4

同被引文献18

引证文献1

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部