期刊文献+

BCY型直流电流比差测量仪及其应用 被引量:2

Type BCY Ratio Error Measuring Instrument for DC Current and Its Applicantions
下载PDF
导出
摘要 BCY型直流电流比差测量仪是直接测量两个直流电流比例误差的新型仪器。本文对其工作原理及造成其测量误差的诸多因素进行了全面的分析,并讨论了用其作为计量标准设备检定直流电流比例仪器及分流器的方法。 The ratio error measuring instrument can read the ratio errorof two DC currents directly.This paper analyses its operating principle andgives a comprehensive study of the factors which cause the measuring errors.Methods of verifying DC ratio instruments and shunts by this standard instru-ment are explained in detail.
出处 《仪器仪表学报》 EI CAS CSCD 北大核心 1992年第1期8-14,共7页 Chinese Journal of Scientific Instrument
  • 相关文献

参考文献2

  • 1王笃志,1989年
  • 2团体著者,1982年

同被引文献9

  • 1任士焱.100kA多通道开口磁调制器式直流大电流比较仪[J].华中理工大学学报,1988,16(1):69-75.
  • 2Ren Shiyan. A 100 kA high precision omsite meas urement calibration device for heavy direct current [J]. IEEE Transactions on Instrument and Measure- ment, 1990, 39(1): 19-22.
  • 3Ren Shiyan. A 300 kA high precision comparator for on-line calibration and measurement[J]. IEEE Trans actions on Instrument and Measurement, 1991, 40(2) : 281-283.
  • 4Ren Shiyan, Yang Huayun, Wang Xiaowei. The the- oretical analysis of open-loop characteristic for double magnetic detector comparator[J].IEEE Transactions on Instrumentation and Measurement, 2005, 54 (2) : 592-594.
  • 5Ren Shiyan, Ding Hengchun. Magnetic shielding ef- fectiveness for comparators [J]. IEEE Transactions on Instrumentation and Measurement, 1995, 44 (2) : 422-424.
  • 6Waki H, Igarashi H, Honma T. Analysis of magnet ic shielding effect of layered shields based on homoge- nization[J]. IEEE Transactions on Instrumentation and Measurement, 2006, 42(4), 847-850.
  • 7任士焱.一种直流大电流计量装置:中国,CNl01571557[P].2009-11-04.
  • 8沈怡.如何正确理解测量不确定度[J].华中电力,1998,11(4):61-63. 被引量:1
  • 9任士焱,张智杰,周小雄,周术.双重磁检测器直流大电流比较仪的稳定性研究[J].华中科技大学学报(自然科学版),2001,29(11):82-84. 被引量:4

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部