摘要
介绍了安徽洛河电厂1号机组电除尘器改造,其一、二电场采用EE型阳极板振打方式后的运行效果,对运行中出现的阳极板撕裂问题进行技术分析,并提出改进建议。
A stroke way for an EE type positive plate of the first and second electric field is adopted after the ESP of unit 1 boiler was reformed.The running situation is introduced.The reason of a crack appearing on the positive plate is analyzed.Some suggestions to avoid the crack is proposed.
出处
《电力环境保护》
2004年第1期34-36,共3页
Electric Power Environmental Protection
关键词
阳极板
振打
电除尘器
positive plate
strike
electrostatic precipitator