摘要 由电路理论知Q =1T∫2π0 u(x- π2 )i(x)dx。u(x- π2 )为电压信号移相 - 90°,而Hilbert变换正好满足此要求。可以借助计算机计算离散Hilbert变换。由采样误差或者电网频率发生漂移导致的测量误差可以采用准同步方法提高精度。采用准同步离散Hilbert变换可以获得较高的无功功率测量精度。 According to the circuit theory,Q=1T∫^(2π)_(0)u(x-π2)i(x)dx. here u(x-π2) is the voltage signal with a phase shift -90°,with which the Hilbert translation can meet. In favor of the computing on computer,the discrete Hilbert translation has been used. The measuring error,which is caused by the sampling error or electrical-net frequency drift error,can be overcomed to a certain extent,by the measurement techniques with quasi-synchronization. The measuring accuracy of reactive power can be highly acquired with quasi-synchronization discrete Hilbert translation.
作者 王柏林 刘华
出处 《机械制造与自动化》 2004年第1期79-81,共3页 Machine Building & Automation
关键词 准同步 离散Hilbert变换 无功功率 quasi-synchronization discrete hilbert translation reactive power