期刊文献+

碳纤维复合材料在髋关节假体中的应用进展 被引量:4

下载PDF
导出
摘要 人工关节假体材料是决定全髋关节成形术(THA)成败的基础.20世纪60年代,Chrnley研制的低摩擦全髋假体使THA成为治疗严重髋关节疾病的有效手段.
出处 《江苏医药》 CAS CSCD 北大核心 2003年第8期614-615,共2页 Jiangsu Medical Journal
  • 相关文献

参考文献16

  • 1[1]Maistrelli GL, Fornasier V, Binnington A, et al. Effect of stem mudulus in a total hip arthroplasty model. J Bone Jinont Surg (Br), 1991,73-B: 43-61.
  • 2[2]Latour RA, Black J. Development of FRP composite structural biomaterial: fatigue strength of the fiber/matrix interfacial bond in in vivo simulated environments. J Biomed Mater Res, 1993,27:1281-1291.
  • 3陈兰田,张静,陈红,齐伯庸,胡明,栾尚文,江昆元,陈明钊.碳股骨头(含碳股骨头表面置换—碳质单杯)应用的润滑理论的研究[J].透析与人工器官,1999,10(4):40-40. 被引量:6
  • 4胡明,陈兰田,栾尚文,陈明钊,张静,车琪,徐扬,赵德本.碳-钛组合式人工股骨头临床应用远期随访结果[J].中华骨科杂志,2002,22(5):272-275. 被引量:9
  • 5[5]Eschbach L. Nonresorbable polymers in bone surgery. Injury,2000,31(suppl): 22-27.
  • 6[6]Morrison C,Macnair R,MacDonald C,et al. In vitro biocompatibility testing of polymers for orthopeadic implants using cultured fiberblasts and osteoblasts. Biomaterials, 1995, 16: 987-992.
  • 7[7]Hunter A,Archer CW,Walker PS, et al. Attachment and proliferation of osteoblastsand fiberblasts on biomaterials for orthopeadic use. Biomaterials, 1995,16: 287-295.
  • 8[8]Lin TW,Corvelli AA,Frondoza CG,et al. Glass peek composite promotes proliferation and osteocalcin production of human osteoblastic cell. J Biomed Mater Res, 1997,36:137-144.
  • 9[9]Brown SA, Hastings RS, Mason JJ, et al. Characterization of short-fiber rienforced thermoplustics for fracture fixation devices. Biomaterials, 1990,11: 541-547.
  • 10[10]Zhang G,Latour RA Jr,Kennedy JM,et al. Long term compressive property durability of carbon fiber-renforced polyetheretherketon composite in physiological saline. Biomaterials, 1996,17:781-789.

二级参考文献7

共引文献15

同被引文献41

  • 1车彪,王凯,刘俊,覃松.髋关节骨性关节炎的临床特征与全髋置换术[J].骨与关节损伤杂志,2004,19(7):439-441. 被引量:14
  • 2贾庆卫,汤亭亭,戴克戎.碳增强的聚醚醚酮人工关节假体材料的磨损性能研究[J].生物骨科材料与临床研究,2004,1(3):1-4. 被引量:10
  • 3陈兰田,江昆元,刘培桐.碳质生物材料的应用研究仍应受到重视(致中华骨科杂志编辑部)[J].中华骨科杂志,1995,15(4):246-246. 被引量:4
  • 4钱正瑛,金伟.人工关节假体材料的研究现状[A].中华医学会医学工程学分会第十次学术年会暨2009中华临床医学工程及数字医学大会论文集[C].2009.
  • 5Pariente JL,Bordenave L,Bareille R,et al.The biocompatibility of catheters and stents used in urology.Prog Urol.1998;8(2):181-187.
  • 6Buford A,Goswami T.Review of wear mechanisms in hip implants:Paper I-General.Mater Desi.2004;25:385.
  • 7Xiong D S,Zhan G,Jin ZG.Friction and wear properties of UHMWPEagainst ion implanted titanium alloy.Surf Coat Techn.2007;201(15):6487.
  • 8Victorian G,Michael R,Robert LB,et al.Reduced wear with oxidized zirconium femoral heads.J Bone Joint Surg Am.2003; 85:105-110.
  • 9Slonaker M,Goswami T.Review of wear mechanisms in hip implantsPAPER-ceramics IG004712.Mater Design.2004;25(5):395.
  • 10Eschbach L.Nonresorbale polymers in bone surgery,Injury.2000; 31(suppl):22-27.

引证文献4

二级引证文献30

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部