期刊文献+

一种对血液动力学影响较小的判断犬脑死亡新方法 被引量:2

A method of deciding brain death with less influence on hemodynamics in dog
下载PDF
导出
摘要 呼吸暂停试验在临床判定脑死亡诊断过程中起十分关键的作用。据报道 ,传统试验方法可引起严重低血压、肺动脉高压、心律失常等并发症。本研究在脑死亡动物模型中以吸入CO2 提高PaCO2 改进呼吸暂停试验 ,旨在减少对血流动力学的影响。结果表明 ,吸入CO2 法能有效刺激呼吸中枢 ,与传统试验方法比较 ,能显著缩短试验时间 ,对血压、心率影响较小 ,试验过程中血管活性药物的需要量无显著增加。更重要的是未发现肺动脉高压。上述结果提示 ,吸入CO2 法较传统方法更加安全 。 Apnea test plays a very important role in diagnosing brain death. But, conventional method may result in severe complications such as hypotension, pulmonary artery hypertension as well as arrhythmia. This research was aiming to minimizing the complications of apnea test by artificial augmentation of PaCO 2 in dog model of brain death. Our results showed that the modified apnea test is a high reliable method. Compared with the conventional way, it efficiently keeps the circulation stabilization without increasing infusion rate of nor-epinephrine (NE) by significantly shorting the testing time. Notably, pulmonary artery hypertension didn't appear during testing. Our finding indicates that artificial augmentation of PaCO 2 is safer than conventional apnea test.
出处 《基础医学与临床》 CSCD 北大核心 2004年第1期74-78,共5页 Basic and Clinical Medicine
基金 卫生部诺华人与环境基金会"中国器官捐献与移植"合作项目基金
关键词 血液动力学 脑死亡 呼吸暂停试验 并发症 brain death apnea test hemodynamics
  • 相关文献

参考文献1

二级参考文献1

共引文献4

同被引文献14

  • 1盛慧球,史以珏,蒋健,赵卫国,张天锡,吴先正.脑死亡判定中呼吸暂停试验临床实施的可行性及对血压和心率的影响[J].中国急救医学,2005,25(6):402-404. 被引量:2
  • 2沈中阳.中国的肝脏移植在希望中艰难前行[J].中国危重病急救医学,2005,17(10):577-579. 被引量:10
  • 3The Quality Standards Subcommittee of the American Academy of Neurology.Practice parameters for determining brain death in adults (summary statement)[J].Neurology,1995,45:10121014.
  • 4Wijdicks E F M.Brain death worldwide accepted fact but not global consensus in diagnostic criteria[J].Neurology,2002,58:20-25.
  • 5Goudreau J L,Wijdicks E F,Emery S F.Complications during apnea testing in the determination of brain death:predisposmg factors[J].Neurology,2000,55:1045-1048.
  • 6Nicolas F,Combes J C,Louvier N,et al.Severe pulmonary arterial hypertension during the apnea test for brain death[J].Transplant Proc,1996,28:375.
  • 7Rudolf J,Haupt W F,Neveling M,et al.Potential pitfalls in apnea testing[J].Acta Neurochir (Wien),1998,140:659-663.
  • 8Jeret J S J,Benjamin J L.Risk of hypotension during apnea testing[J].Arch Neurol,1994,51:595-599.
  • 9Lang C J.Apnea testing by artificial CO2 augmentation[J].Neurology,1995,45:966-969.
  • 10Quality Standards Subcommittee of the American Academy of Neurology.Practice parameters for determining brain death in adults.Neurology,1995,45(5):1012

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部