摘要
为了解三峡电站 5 0 0kV八回出线架空跨越永久船闸实际产生的电磁环境 ,实测并分析了永久船闸区域的电磁环境参数 ,结果表明现行最高水位下闸室中 ,线下船舶上的最大工频电场强度、船闸周边的最大工频电场强度和磁感应强度分别为 2 .0 1、1.82kV/m和 1.17μT ,均小于我国环保标准中规定的限值 ;无线电干扰水平也非常低。不影响闸室船上通信及中、短波广播、电视接收。
In order to know the EM environment at the condition of crossing the ship-gate with eight 500kV overhead transmission lines, The EM environment parameters at ship-gate area are analysis and measured. The results show that The max. power frequency electric field and magnetic induction intensity on ship and around the gate are respectively 2.01、1.82kV/m and 1.17μT. They are lower than the limit value of standard. The radio interference is also low. The communication, radio broadcast and TV are not affected.
出处
《高电压技术》
EI
CAS
CSCD
北大核心
2004年第2期40-42,共3页
High Voltage Engineering