期刊文献+

标量网络分析仪误差校正分析及其应用 被引量:1

Scalar Network Analyzer's Error Calibration Analysis and Application
下载PDF
导出
摘要  为了消除标量网络分析仪在测量过程中的系统误差,提高测量精度,采用误差分析及校正模型,用数值分析的方法去除系统误差,降低随机误差.理论计算和实际测量结果都表明,测量精度明显提高.该误差分析理论及误差测量方法在标量网络分析仪中得到了较好的应用,提高了仪器的性能. In order to eliminate system error in the measuring process of scalar network analyzer and improve measuring precision, by using error analysis, correcting model and numerical analysis, the system error and the random error are eliminated. The results of theoretic calculation and measurement show that the measuring precision is obviously improved. The proposed theory of error analysis and the method of error measurement are well applied in scalar network analysis and the performance of apparatus is improved.
作者 陈伟 王桂琼
出处 《测试技术学报》 EI 2004年第1期69-73,共5页 Journal of Test and Measurement Technology
关键词 标量 网络分析仪 误差校正 误差模型 S参数 测量精度 双口网络 network analyzer system calibration calibration model %S%-parameter measurement
  • 相关文献

参考文献3

  • 1Agilent Corporation. Agilent AN 1287-3 Applying Error Correction to Network Analyzer Measurements[EB/OL]. http://literature.agilent.com/litweb/pdf/5965-770. 9E.pdf.2002-03-27/2003-10-08.
  • 2Agilent Corporation. Agilent Specifying Calibration Standards for the Agilent 8510 Network Analyzer[EB/OL]. http://cp.literature.agilent.com/litweb/pdf/5956-4352.pdf.2001-09-21/2003-10-08.
  • 3梁军,刘旺,孙圣和.网络分析仪误差模型及应用[J].计量技术,2002(6):3-6. 被引量:6

二级参考文献1

  • 1郑君里 杨为理 等.信号与系统[M].高等教育出版社,1991..

共引文献5

同被引文献7

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部