摘要 生化传感器一直是传感技术领域一个非常活跃的研究前沿 ,特别是近十多年以来 ,随着各种新原理新技术的发展和出现 ,生化传感器的发展呈现出商品化、微型化、集成化、智能化等许多新特点 ,本文介绍当前生化传感器发展的新特点 ,并对其发展的新趋势也进行了探讨。 Biochemical sensor is one of the most attractive fields in sensors research.Especially in recent decade,with the development and occurrence of all kinds of novel theory and technology,biochemical sensors show a lot of novel characteristics,including commercialization,miniaturization,integration,and intelligence,in their development.New characteristics of biochemical sensors are described,and their novel trends are discussed.
出处 《测控技术》 CSCD 2004年第3期1-4,共4页 Measurement & Control Technology
基金 国家自然科学重点基金 (6993 60 10 ) 国家自然科学基金重大项目 (2 0 2 990 3 0 )的资助
关键词 生化传感器 商品化 微型化 集成化 智能化 生物芯片 biochemical sensors commercialization miniaturization integration intelligence biochip
  • 相关文献

参考文献4

二级参考文献21

  • 1Lacher N A, Garrison K E,Martin R S, et al . Microchip capillary eletrophoresis/electrochemistry [ J ]. Electrophoresia, 2001, 22( 11 ) : 2526 - 2536.
  • 2Woolley A T,Lao k,Glazer A N, et al. Capillary electrophoresis chips with integrated dectrochemical detection[J]. Anal Chem,1998,70(4) :684 - 688.
  • 3Wang J. Electrochemical detection for microacale analytical systems: a review[ J ]. Talanta, 2002,56 (2) : 223 - 231.
  • 4Wang J, Tian B, Sahlin E. Integrated electrophoresis chips/araperometric detection with sputtered gold working electrodes[J]. Anal China, 1999,71 (17) :3901-3904.
  • 5Wang J, Chatrathi M P, Tian B, et al . Microfabrlcated electrophoresis chips for simultaneous bioassays of glucose, uric acid,ascorhic acid, and acetaminophen[ J ]. Anal Chem, 2000,72 ( 11 ) :2514 - 2518.
  • 6Wang J, Chatrathi M P, Tian B. Microseparation chips for performing multienzymatic dehydrogenase/oxidase assays: simultaneous electrochernical measurement of ethanol and glucose [ J ]. Anal Chem, 2001,73(6) : 1296 - 1300.
  • 7Graβ B, Neyer A,Joehnck M, et al . A new PMMA-microchip device for isotachophoresis with integrated conductivity detector[J ].Sensors and Actuators B,2001,72(3) :249 - 258.
  • 8Pumera M,Wang J,Opekar F, et al . Contactleaa conductivity detection for rnicrochip capillary electrophoresis [ J ]. Anal Chem,2002,74(9) : 1968 - 1971.
  • 9Oki A,Adachi S,Takamura Y, et al . Electroosmosis injection of blood serum into biocompatible microcapillary chip fabricated on quartz phte[J]. Electrophoresis, 2001,22(2) :341 - 347.
  • 10Arquint P,Kouddka-Hep M, Van Der Schoot B H, et al . Micromachined analyzers on a silicon chip[J]. Clin Chem, 1994,40(9) : 1805 - 1809.

共引文献47

同被引文献8

引证文献2

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部