摘要
介绍了机场货运站自动喷水灭火系统、消火栓以及其他消防设施的设置原则 ,论述了货运站自动喷水灭火系统与防火分区的关系、危险区域的划分的原则 。
Introduction on setting principle of automatic sprinkler systems,standpipe & hydrant systems and others fire protection facilities in airport terminal cargo,discourse upon the relations between automatic sprinkler systems with fire area,division principle of hazard zone and on design and selecting automatic sprinkler systems,standpipe & hydrant systems and others fire protection facilities about technique condition.
出处
《消防科学与技术》
CAS
2004年第2期143-148,共6页
Fire Science and Technology