摘要 针对采用有限大小探测器的共焦显微系统,利用两区相位型滤波器提高系统的纵向分辨率。在实验上,采用1透射式液晶空间光调制器实现了对共焦显微系统照明光场位相的动态调制,测量了探测针孔直径分别为5μm、10μm和15μm时,共焦显微系统纵向分辨率随滤波器参数的变化规律。实验结果说明,在探测器为有限大小的情况下,利用该滤波器可以使共焦显微系统的纵向分辨率提高17.8%。另外,从实验结果还可以看出,滤波器的性能受到探测针孔尺寸的影响。 For a confocal microscope with a finite-sized detector, the improvement in axial resolution by a phase-only filter with two zones was experimentally investigated. The illumination path of the confocal system was dynamically modulated by a liquid-crystal spatial light modulator operating in a transmission-only mode. The variations of axial resolution with filter parameters were measured, when pin-hole diameter were 5 μm, 10 μm and 15 μm, respectively. The experimental results show that the axial resolution of confocal microscope can be improved by 17.8%, in the case of a finite-sized detector. It can be concluded that filter performance is influenced by pinhole size.
出处 《光电子.激光》 EI CAS CSCD 北大核心 2004年第4期420-422,共3页 Journal of Optoelectronics·Laser
基金 教育部南开大学 天津大学科技合作基金资助项目
关键词 共焦系统 纵向分辨率 共焦显微术 相位型滤波器 探测器 Focusing Light modulators Liquid crystal displays Optical filters Optical resolving power
  • 相关文献

参考文献9

  • 1[1]LI Cheng-jun, ZENG Shao-qun, LUO Qing-ming, et al.Phosphorescence lifetime measurement using confocal microscopy[J].J.of Optoelectronics·Laser(光电子·激光),2002,13(2):165-168.
  • 2[2]ZHANG Jie,TAN Jiu-bin.Micro detection system with nm resolution using self-focal-conforal microscope[J].J.of Optoelectronics·Laser(光电子·激光),2002,13(4):374-377.
  • 3[3]DENG Xiao-qiang,WANG Gui-ying,XU Zhi-zhan.Super resolving phase-only filters in confocal scanning imaging system[J].Optik,2000,111(11):503-507.
  • 4[4]T R M Sales,G M Morris.Fundamental limits of optical superresolution[J].Opt.Lett.,1997,22(9):582-584.
  • 5[5]M Martinez-Corral.A Pons,M T Caballero.Axial apodization in 4pi-confocal microscopy by annular binary filters[J].J.Opt.Soc.Am.A,2002,19(8):1532-1536.
  • 6[6]G Boyer.New class of axially apodizing filters for confocal scanning microscopy[J].J.Opt.Soc.Am.A,2002,19(3):584-589.
  • 7[7]M A A Neil,R Juskaitis,T Wilson,et al.Optimized pupil-plane filters for confocal microscope point spread function engineering[J].Opt.Lett.,2000,25(4):245-247.
  • 8[8]T R M Sales, G M Morris. Axial superresolution withphase-only pupil filters[J].Opt.Comm.,1998,156(5/6):227-230.
  • 9[9]T Wilson,A R Carlini.Size of the detector in confocal imaing systems[J].Opt.Lett.,1987,12(4):227-229.