铁(Ⅲ)的滴定计算分析法测定 被引量:3

APPLICATION OF CALCULATION TITRIMETRY TO THE REDOX DETERMINATION OF FERRIC IRON
下载PDF
导出
摘要 在Fe2+存在的条件下,以铂电极为指示电极、Ce4+标准溶液为滴定剂,对氧化还原滴定计算分析法测定Fe3+进行了研究。结果表明,电极的系统误差是影响结果准确度的主要因素。 The redox determination of ferric iron (such as in the analysis of iron ore) was reported to be carried out by potentiometry using Pt-electrode as the indicating electrode and standard ceric solution as titrant and in the presence of a definite amount of ferrous iron. By recording the volumes of titrant V_i with their corresponding values of potential E_i after each increment of 0.50ml of the titrant before the equivalent point and substituting the values into the derived formula, the concentration of ferric iron can be calculated. It was found that the cleaning of the electrode surface, to maintain consistent blank potential values when tested with distilled water, is essential to eliminate systematic error of the working electrode.
机构地区 同济大学化学系
出处 《理化检验(化学分册)》 CAS CSCD 北大核心 2004年第3期164-165,168,共3页 Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
基金 同济大学理科发展基金资助项目
关键词 铁(Ⅲ) 滴定计算分析法 氧化还原电位滴定 铁矿石 Redox potentiometric titrimetry Calculation titrimetry Ferric iron Iron ore