抛物线型无损耗传输线的时域灵敏度分析 被引量:5

Time-domain sensitivity analysis of parabolic lossless nonuniform transmission lines
下载PDF
导出
摘要 频域灵敏度分析只能适用于线性网络。为了解决含非线性的问题,提出了一种由频域灵敏度公式求线性元件时域灵敏度公式的方法。基于伴随网络法和已有的频域灵敏度公式,推导出了抛物线型无损耗传输线的时域灵敏度公式,较好地解决了这类非均匀线的灵敏度求解问题。 In order to deal with nonlinearity, a method is presented to derive the time-domain sensitivity formulas of linear circuit elements fromthe frequency-domain sensitivity formulas. Based on adjoin networkmethod and the known sensitivity formulas in frequency domain, the sensitivity formulas of parabolic lossless nonuniform transmission line are obtained in time domain. These formulas can be used to confirm the key parameters and to optimize design for linear and nonlinear networks containing parabolic lossless nonuniform transmission lines.
出处 《华北电力大学学报(自然科学版)》 CAS 北大核心 2004年第2期5-8,共4页 Journal of North China Electric Power University:Natural Science Edition
基金 河北省自然科学基金资助项目(5033424).
关键词 抛物线型无损耗传输线 非线性 时域灵敏度分析 偏微分方程 nonuniform transmission line adjoint network method sensitivity analysis
  • 相关文献

参考文献7

  • 1任宇,梁贵书,董华英.抛物线型无损非均匀传输线的灵敏度研究[J].华北电力大学学报(自然科学版),2003,30(2):30-33. 被引量:3
  • 2Kobayshi K, Nemoto Y, Sato R. Kuroda's identity for nonuniform transmission lines [J]. IEEE Trans. on MTT,1981,29 (2): 81-86.
  • 3Kobayshi K, Nemoto Y, Sato R. Euivalent circuit of binomial form Nnonuniform coupled transmission lines [J]. IEEE Trans on MTT, 1981,29 (8): 817-824.
  • 4Saied M M, Alfuhaid A S, Elshandwily M E. Domain analysis of electromagnetic transients on nonuniform lines[J]. IEEE Trans on Power Delivery, 1990,5 (4): 2072-2079.
  • 5K Lu.An efficient method for analysis of arbitray nonuniform transmission lines[J].IEEE Trans on MTT, 1997,45( 1 ):9-14.
  • 6Cheldavi A, Kamarei M, Naemi S S. Analysis of coupled transmission lines with power-Law characteristic impedance [J]. IEEE Trans on MTT, 2000,42 (3): 308-312.
  • 7Mao J, Kuh E S. Fast simulation and sensitivity analysis of lossy transmission lines by the method of characteristics [J].IEEE Trans on Circuit and System-I, 1997,44 (5): 391-401.

二级参考文献1

  • 1特密斯GC 拉帕特雷 贾毓聪 韩宝珍译.GW电路综合与设计导轮[M].北京:人民邮电出版社,1985.391-399.

共引文献2

同被引文献25

  • 1梁贵书,王勇,董华英.含无损耗指数传输线网络的频域灵敏度分析[J].华北电力大学学报(自然科学版),2006,33(1):7-9. 被引量:6
  • 2李世琼,宗伟.有损均匀传输线的PSpice仿真分析[J].电气电子教学学报,2007,29(3):32-34. 被引量:4
  • 3Oufi E A, Alfuhaid A S, Saied M M. Transient analysis of lossless single-phase nonuniform transmission lines [J].IEEE Trans on MTT, 1994,9 (3): 1694-1700.
  • 4Cheldavi A, Kamarei M, Naeini S S. Analysis of coupled transmission lines with power-law characteristic impendace [J]. IEEE Trans onMTT, 2000,42 (3): 308-312.
  • 5Kobayshi, Nemoto, Sato R. Kuroda's identity for nonuniform transmission line [J].IEEE Trans on MTT, 1981,29(2):81-86.
  • 6Endo I, Nemoto Y, Sato R. Equivalent representations of lossy nonuniform transmission lines [J]. IEEE Trans on MTT, 1983,31 (6): 457-426.
  • 7KobayshiK,NemotoY,SatoR.Kuroda's identity for nonuniform transmission lines [J].IEEE Trans.on MTT,1981,29 (2):81-86.
  • 8Kobayshi K,Nemoto Y,Sato R.Euivalent circuit of binomial form nonuniform coupled transmission lines [J].IEEE Trans.on MTT,1981,29 (8):817-824.
  • 9Curtins H,Shan A V.Step response of lossless nonuniformtransmission lines with power-law characteristic impedance function[J].IEEE Trans.onMTT,1985,33(11):1210-1212.
  • 10Palusinski O A,Lee A.Analysis of transients in nonuniform and uniform multiconductor transmission lines [J].IEEE Trans.on MTT,1989,37 (1):127-138.

引证文献5

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部