期刊文献+

机敏混凝土结构变形的自诊断 被引量:6

Self-monitoring of the deformation in smart concrete structures
下载PDF
导出
摘要 从理论和实验两方向证明 :利用结构的受力变形特点和CFRC的功能特性 ,合理地敷设CFRC ,不但可实现机敏混凝土结构变形的自诊断 ,而且可大大提高其灵敏系数和稳定性 ,同时也实现了温度补偿 . When the deformation of carbon fiber reinforced concrete (CFRC) was within the range of elasticity,its resistance increased reversibly under tension strain and decreased reversibly under compression strain. According to the stress-strain condition at different parts,when CFRC was laid selectively,not only the self-monitoring of the deformation in smart concrete structure was attained,but also the sensitivity and the stability were improved greatly. This approach was verified theoretically and experimentally and some ideas of further investigations of smart concrete structures were provided.
出处 《华中科技大学学报(自然科学版)》 EI CAS CSCD 北大核心 2004年第4期30-31,55,共3页 Journal of Huazhong University of Science and Technology(Natural Science Edition)
基金 国家自然科学基金重点项目资助 (5 0 2 380 4 0 )
关键词 碳纤维增强混凝土 变形 自诊断 压敏效应 carbon fiber smart concrete self-monitoring deformation compression-sensitivity
  • 相关文献

参考文献6

  • 1Chen P W, Chung D D L. Concrete as a new strain/ stress sensor. Composites, Part B, 1996, 27B: 11-23.
  • 2Chung D D L. Self-monitoring structural materials. Mater Sci Eng Rrv , 1998, 22(2): 57-78.
  • 3Wang X, Fu X, Chung D D L. Strain sensing using carbon fiber. J Mater Res, 1999, 14(3): 790-802.
  • 4Wen S, Chung D D L. Carbon fiber-reinforced cement as a strain-sensing coating. Cement and Concrete Research, 2001, 31:665-667.
  • 5Wen Sihai, Chung D D L. Uniaxial compression in carbon fiber-reinforced cement sensed by electrical resistivity measurement in longitudinal and transverse directions. Cement and Concrete Research, 2001, 31: 297 - 301.
  • 6Wang X, Chung D D L. Short carbon fiber reinforced epoxy coating as piezoresistive strain sensor for cement mortar. Sensors and Actuators, 1998, A71: 208 - 212.