摘要
分析了变风量系统和定风量系统的特点 ,指出在计算冷负荷、送风量、设计风管系统及控制系统等方面应注意的问题 。
The features of Variable Air Volume system and CAV system are analyzed.The problems to pay attention in calculating the cool load and air volume to supply,in designing the size of pipe system and control system are pointed out.Some measures for the design of Variable Air Volume system are provided.
出处
《流体机械》
CSCD
2004年第3期24-27,共4页
Fluid Machinery
关键词
变风量系统
冷负荷
静压复得
控制
variable air volume system
cool load
static pressure to regain
control