期刊文献+

支抗种植体长度对骨界面应力分布的影响 被引量:22

The effect of different anchorage implant length on stress distribution in implant-bone interface
下载PDF
导出
摘要 目的 :研究不同长度支抗种植体对骨界面应力分布的影响 ,以供临床筛选合适的种植体。方法 :用三维有限元方法给种植体施加150g近远中方向的载荷 ,分别对长度为7mm、10mm、15mm的支抗种植体 -骨界面进行应力分析。结果 :三种长度种植体颈部的Von-Mises应力值分别为0.5450MPa、0.5330MPa、0.5320MPa;位移值分别为0.1690μm、0.1630μm、0.1610μm。结论 :在种植体承受侧向力载荷时 ,增加种植体长度可提高其承载能力 ,临床上在选择正畸支抗种植体时 ,应尽量选择长种植体作正畸支抗体。 Objective: To investigate the effect of different implant length on stress distribution in implant-bone interface, thus selecting the most appropriate length for orthodontic anchorage. Method: To analysis the stress and strain in implant-bone interface for implants with different length (7mm、10mm、15mm), which was 150 grams loaded mesiodistally, employing 3-dimesion finite element analysis method. Results:The Von -mises stress at cervix of these three implant length were 0.5450MPa、0.5330 MPa、0.5320 MPa . The alveolar bone deformation at the cervix of implants were 0.1690μm、0.1630μm、0.1610μm respectively. Conclusion: The increase of the length of implants could efficaciously enhance the ability, which the implants could bear a force. Thus the implants of the enough length must be selected clincally.
出处 《中国口腔种植学杂志》 2003年第3期112-115,共4页 Chinese Journal of Oral Implantology
基金 广东省医学科学技术研究基金资助项目项目编号A2002911
关键词 支抗种植体 骨界面 应力分布 三维有限元 牙齿缺失 义齿 Implant anchorage Three-dimesion finite element analysis Anchorage implant-bone interface
  • 相关文献

参考文献8

  • 1兰泽栋,林珠,龙红月,周磊.支抗种植体—骨界面三维有限元模型的建立[J].中国口腔种植学杂志,2003,8(2):57-60. 被引量:19
  • 2[2]Meijer HJ, Starman FJ, Boman F et al. Stress distribution around dental implants: influence of superstructure, length of implants, and height of mandible. J Prosthet Dent, 1992; 68(1): 96~ 100
  • 3[3]Lum LB. A biomechanical rational for the use of short implants. J. Oral Implant, 1991; 17(2): 126~ 131
  • 4[4]Lum LB, Osier JF. Load transfer from endosteal implants to supporting bone: an analysis using statics. Part two: Axial loading. J Oral Implantol, 1992; 18(4): 349~ 353
  • 5[5]Lum LB, Osier JF. Load transfer from endosteal implants to supporting bone: an analysis using statics. Part one: Horizontal loading. J Oral Implantol, 1992; 18(4):343~ 353
  • 6[6]Goodacre CJ, Kan JY, Rungcharassaeng K et al. Clinical complications of osseointegrated implants. J Prosthet Dent, 1999 May; 81(5): 537~ 552
  • 7[7]Grunder JH. A 3-year prospective multicenter follow-up report on the immediate and delayed-immediate placement of implants. Int J Ora Maxillofac-Implants. 1999 Mar-Apr; 14(2): 210~ 216
  • 8张少锋,马轩祥,欧阳官,徐君伍,刘宝林.种植体长度和直径对种植全口义齿应力的影响[J].实用口腔医学杂志,1997,13(3):199-201. 被引量:41

二级参考文献2

  • 1中岛功.日本人下颌骨の齿牙欠如域における内部构造に关する研究[J].齿科学报,1991,91(4):419-448.
  • 2张少锋,马轩祥,欧阳官,徐君伍,刘宝林.种植全口义齿的应力分布特点[J].实用口腔医学杂志,1997,13(3):194-196. 被引量:18