摘要
根据液化气站火灾特点 ,提出了防止及改进措施 ,主要针对液化气储罐下部液态泄漏 ,采用水封隔离封堵法 ,同时转移液化石油气 ,解决了及时扑救的措施 ,为遏制火灾事故的进一步扩大 ,防止爆炸事故的发生 ,为液化气储站的抢险工作赢得时间。
According to the features of fire hazard in LPG station,the measure of protection and improved was put forward.To against the liquid leakage of the LPG storage tank.,water seal measure was adopted and the LPG was tranferred at the meantime.The remedial measure was settled and the fire hazard was inhibited to further expanding.The explosion accident was avoided and the time of rescue work for LPG station was gained.
出处
《压力容器》
2004年第3期54-55,共2页
Pressure Vessel Technology