期刊文献+

红外多波长无创人体血糖检测技术研究

The Infrared Multiwavelength Blood Glucose Detecting Research
下载PDF
导出
摘要 红外多波长血糖检测是利用人体血管红外线的热梯度光谱信息,通过数学模型求出血糖浓度的无创伤的检测方法,特别适用于长期、频繁的血糖检测。研究了红外多波长无创人体血糖检测关键技术,取得了实验室成果。 The infrared multiwavelength blood glucose detecting is a kind of noninvasive detecting method which using the information of infrared thermal gradient spectrum through the blood vessel ,and measuring the concentration of glucose in the blood by using mathematical model.It shows a lot of benefits in long-term or frequent blood glucose detecting. In this article,the key technology in infrared multiwavelength noninvasive blood glucose detector is discussed,and the technology has heen used in the multiparameter remote health care successfully.
出处 《咸阳师范学院学报》 2004年第2期23-25,共3页 Journal of Xianyang Normal University
关键词 红外 多波长 血糖 检测 infrared multiwavelength blood glucose detecting
  • 相关文献

参考文献8

二级参考文献33

  • 1[1]Arnold M A, Burmeister J J, Small G W. Phantom glucose calibration models from simulated noninvasive human near-infrared spectra[J]. Anal Chem,1998 May 1;70(9):1773~1781.
  • 2[2]Klonoff D C. Noninvasive blood glucose monitoring[J]. Diabetes Care,1997 Mar;20(3):433~437.
  • 3[3]Zheng P, Kramer C E, Barnes C W,et al.. Noninvasive glucose determination by oscillating thermal gradient spectrometry[J]. Diabetes Technol Ther, 2000 Spring;2(1):17~25.
  • 4[4]Chou C, Lin P K.Chou C, Lin P K. Laser photoacoustic determination of physiological glucose concentrations in human whole blood[J]. Med Biol Eng Comput,1993 May;31(3):284~290.
  • 5[5]Editor. China medical device information[J]. 2000.6(6):13.
  • 6[6]Klonoff D C. Noninvasive blood glucose monitoring[J]. Diabetes Care 1997 Mar;20(3):433~437.
  • 7[7]Robinovitch N. Noninvasive glucose determination by Reverse iontophresis fluid extraction from skin[J].Diabetic Care, 1982.5:259~265.
  • 8[8]Jussi T H,Harri K,Risto M. Non-invasive glucose measurement based on selective near infrared absorption;requirements on instrumentation and spectral range[J]. Measurement, 1998.24:173~177.
  • 9[9]Pan S, Chung H, Arnold Ma, Small G W. Nearinfrared spectroscopic measurement of physiological glucose levels in variable matrices of protein and triglycerides[J]. Anal Chem,1996. 68:112~135.
  • 10[10]Muller C A, Mertes B,Fischbaucher C,etal.Non-invasive blood glucose monitoring by means of near infrared methods for improving the reliability of the calibration models[J]. Int J Artif Organs, 1997.20:285~290.