本文介绍了利用APPLe-Ⅱe机及其辅助设备,研制出可以进行强度——时间曲线检查的自动分析电诊断仪,通过对587块受累肌肉的测定并将其结果与肌电图检查结果对比,显示出该仪器能克服同类产品在操作上存在的一些不足之处,具有自动显示、分析、记录、打印等功能,有利于康复评定、科研、教学的开展和应用。
It was reported that an intensity-time electrodiagnostic equipment was made by using Apple-Ⅱ computer combined with other hardware. By this equipment, 587 muscles were examined, and the results were compared with those of electromyographer, suggesting that it can operatively overcome shortcomings of the same kinds of products. It has the function of automatic display, analysis, recording and printing, and can be widely used in rehabilitation assessment, research and teaching.