摘要
应用光阻颗粒计数仪(HIAC/ROYCO)初步考察国内部份注射用抗生素制剂及国外样品104批,并对质量标准,颗粒大小及数量,控制范围作初步探讨。
Particulate contamination in antibiotic injection vials including 21 pharmaceutical preparation of 100 samples from different sources, using a light blockage particle analyzer(HIAC/ROYCO)has been determined. Lower levels of particu-late contamination were found in antibiotic solution for injection, such as gentamicin sulfate for injection and kanamycin sulfate for injection, as compared with antibiotic powders for injection. The numbers of particles in penicillin potassium packed in different strength were revealed that the higher numbers of particles were relative to higner strength and vice versa. Results showed that the level of particulate contamination also fell well within the limits set by the USP XXII Edition for Small Volume Parenterals.
出处
《中国抗生素杂志》
CAS
CSCD
北大核心
1992年第1期48-54,共7页
Chinese Journal of Antibiotics
关键词
注射剂
微粒物质
抗生素
Light blockage particle size analyzer
Electrical sensing zoee particle analyzer
Imageana lyzer with optical microscope
Particulate matter